Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: OUTLAW EXTERIORS

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of OUTLAW EXTERIORS in JOSEPHINE CROSSING, BILLINGS, MT 59101 (NAICS 236115). OSHA activity number 336786181.

Watch Outlaw Exteriors — free Get an email when a new federal OSHA severe-injury report for Outlaw Exteriors is published. One employer, no account, unsubscribe in one click.
Establishment
OUTLAW EXTERIORS
Site address
JOSEPHINE CROSSING
City
BILLINGS
State
MT
ZIP
59101
Mailing
2161 ELDORADO, BILLINGS, MT 59102
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
236115
Employees
4
Ownership type
A

4 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.100(a):  Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets:    a) Construction Site: On or about October 10, 2012 and at times prior, an employee was working on a residential construction site and not wearing a hard hat and was exposed to overhead struck-by hazards from construction activities on the roof.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.404 F06

Serious Gravity 5 2 instances 1 exposed
Issued
Abate by
Penalty
Initial $2000.00 · Current $1000.00 Reduced
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous:       a) Construction Site: On or about October 10, 2012 and at times prior, an employee was exposed to an electrocution hazard while using an electrical extension cord that had the grounding prong removed.    b) Construction Site: On or about October 10, 2012 and at times prior, an employee was exposed to an electrocution hazard while using an electrical 3-way adapter that had the grounding prong removed.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.405 G02 IV

Serious Gravity 5 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1926.405(g)(2)(iv):  Flexible cords were not connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws:    a) Construction Site: On or about October 10, 2012 and at times prior, an employee was exposed to an electrocution hazard while using an electrical extension cord with no strain relief.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B13

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1200.00 · Current $600.00 Reduced
29 CFR 1926.1053(b)(13): The top or top step of a stepladder was used as a step:    a)  Construction Site: On or about October 10, 2012 and at times prior, an employee stood on the top step of a 6 foot stepladder.
Recent events (2)
  • — I (S) $600
  • — Z (S) $1200

CBH HOMES

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336786181.