OSHA Inspection: D&L MOLDS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of D&L MOLDS, INC. in 1100 DEARFOOT PARKWAY, RAINBOW CITY, AL 35906 (NAICS 333511). OSHA activity number 336805197.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch D&L Molds, INC. — free Get an email when a new federal OSHA severe-injury report for D&L Molds, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
D&L MOLDS, INC.
Site address
1100 DEARFOOT PARKWAY
City
RAINBOW CITY
State
AL
ZIP
35906
Mailing
1100 DEERFOOT PARKWAY, RAINBOW CITY, AL 35906
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
333511
Employees
11
Ownership type
A

5 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 1 instance 4 exposed
Issued
Oct 17, 2012
Abate by
Dec 20, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:      (a) On or about 10/11/12 - Main Shop, an energy control program had not been established for employees performing servicing and maintenance activities inside the HAAS CNC machines.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.212 A01

Serious Gravity 10 2 instances 4 exposed
Issued
Oct 17, 2012
Abate by
Oct 24, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    (a) On or about 10/11/12 - Main Shop, a horizontal band saw did not have the unused portions of the blade guarded.    (b) On or about 10/11/12 - Main Shop, a pedestal drill press did not have the chuck guarded.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.215 B09

Serious Gravity 5 2 instances 3 exposed
Issued
Oct 17, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one-fourth inch:      (a) On or about 10/11/12 - Grinding Room, the tongue guards on the pedestal-mounted abrasive grinder were not adjusted to at least one-fourth inch.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.242 B

Serious Gravity 5 6 instances 4 exposed
Issued
Oct 17, 2012
Penalty
Initial $1,600 · Current $800 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:      (a) On or about 10/11/12 - Main Shop, compressed air was used with an output of 100 p.s.i. to clean off parts.
Recent events (2)
  • — I (S) $800
  • — Z (S) $1600

1910.1200 E01

Other-than-serious 2 instances 3 exposed
Issued
Oct 17, 2012
Abate by
Dec 20, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met:      (a) On or about 10/11/12 - Main Shop, a written hazard communication program had not been developed and implemented for employees who were exposed to hazardous chemicals including, but not limited to, acetone and propane.