Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,198,892Inspections Most recent open 2026-09-03 Last loaded 2026-09-07

OSHA Inspection: P. SALAZAR CONSTRUCTION AND ROOFING

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of P. SALAZAR CONSTRUCTION AND ROOFING in 5274 SOUTH STAPLES, CORPUS CHRISTI, TX 78413 (NAICS 238160). OSHA activity number 336818786.

What this inspection record means

OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch P. Salazar Construction and Roofing for free Get an email when a new federal OSHA severe-injury report for P. Salazar Construction and Roofing is published. One employer, no account, unsubscribe in one click.
Site address
5274 SOUTH STAPLES
City
CORPUS CHRISTI
State
TX
ZIP
78413
Mailing
4917 OLYMPIA DR, CORPUS CHRISTI, TX 78413
Inspection type
Programmed Related (I)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
Non-union (B)
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
Private (A)

2 citations on file for this inspection.

1926.453 B02 V

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 18, 2013
Abate by
Apr 11, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.453(b)(2)(v):     A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift:Note:  As of January 1, 1998, subpart M of this part (1926.502(d)) provides that body belts are not acceptable as part of a personal fall arrest system.  The use of a body belt in a tethering system or in a restraint system is acceptable and is regulated    At this work place, an employee conducting building operations on the northside of the building under renovation was elevated in a JLG T350 aerial lift, at the height of approximately 8 feet without a personal fall arrest system in place.
Recent events (1)
  • · Z (S) $1600

1926.501 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Mar 18, 2013
Abate by
Apr 11, 2013
Penalty
Initial $1,600 · Current $1,600
29 CFR 1926.501(b)(1):     Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems.    At this workplace, an employee remodeling a roof on the southside of a building under renovation at the height of approximately 8 feet did not have a personal fall protection system in place.
Recent events (1)
  • · Z (S) $1600

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 336818786.