Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,214Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: KITS FOUNDRY AND MACHINE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of KITS FOUNDRY AND MACHINE, INC. in 779 EAST 1100 NORTH, SHELLEY, ID 83274 (NAICS 331511). OSHA activity number 336820980.

Watch Kits Foundry AND Machine, INC. — free Get an email when a new federal OSHA severe-injury report for Kits Foundry AND Machine, INC. is published. One employer, no account, unsubscribe in one click.
Site address
779 EAST 1100 NORTH
City
SHELLEY
State
ID
ZIP
83274
Mailing
779 EAST 1100 NORTH, SHELLEY, ID 83274
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331511
Employees
10
Ownership type
A

8 citations on file for this inspection.

1910.23 C01

Serious Gravity 1 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $1020.00 · Current $700.00 Reduced
29 CFR 1910.23(c)(1):  Open-sided floors and/or platforms four feet or more above adjacent floor or ground level were not guarded with standard railings (or equivalent) and toeboards:      (a)  Break room ceiling, on or about October 10, 2012, and at times prior thereto, employees accessed the top of the Break room to retrieve molds being stored there.  The fall hazard was approximately eight feet, two inches to a concrete floor.    Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $700
  • — Z (S) $1020

1910.110 D10

Serious Gravity 1 3 instances 5 exposed
Issued
Penalty
Initial $1020.00 · Current $700.00 Reduced
29 CFR 1910.110(d)(10):   Precautions were not taken to prevent damage to LP gas system(s) from vehicular traffic:      (a) Southeast corner of foundry buildings, on or about October 10, 2012, and at times prior thereto, approximately 1000 gallon propane storage tank was not protected from vehicular traffic.    (b) Center-East side of the foundry buildings, on or about October 10, 2012, and at times prior thereto, approximately 1000 gallon propane storage tank was not protected from vehicular traffic.    (c) Southwest side of the foundry buildings, on or about October 10, 2012, and at times prior thereto, approximately 1000 gallon propane storage tank was not protected from vehicular traffic.    Note: No abatement certification is required.  Items were corrected at the time of the inspection.
Recent events (2)
  • — I (S) $700
  • — Z (S) $1020

1910.132 A

Serious Gravity 5 3 instances 8 exposed
Issued
Abate by
Penalty
Initial $1700.00 · Current $1200.00 Reduced
29 CFR 1910.132(a):  Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    (a) Furnace Area, on or about November 14, 2012, and at times prior thereto, employees, fueling the furnace with metal scrap, were not required to wear protective equipment to protect arms from contact with metal sparks.    (b)  Pouring area, on or November 14, 2012, and at times prior thereto, employees assisting with the pouring of molten metal, were not required to wear fire retardant coveralls to protect them from molten metal splashes and back flashes from flames from off-gassing fires.    (c)  Outside, Scrap Metal Area, on or about October 10, 2012, and at times prior thereto, employees cutting up metal scrap, were not required to wear protective equipment to protect arms from contact with metal sparks.    Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1700

1910.132 D

Deleted Serious Gravity 5 3 instances 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d):  The employer did not assess the workplace to determine if hazards were present, or were likely to be present, which would have necessitated the use of personal protective equipment:    (a) Furnace Area, on or about November 14, 2012, and at times prior thereto, employees, fueling the furnace with metal scrap, were not required to wear protective equipment to protect arms from contact with metal sparks.    (b)  Pouring area, on or November 14, 2012, and at times prior thereto, employees assisting with the pouring of molten metal, were not required to wear fire retardant coveralls to protect them from molten metal splashes and back flashes from flames from off-gassing fires.    (c)  Outside, Scrap Metal Area, on or about October 10, 2012, and at times prior thereto, employees cutting up metal scrap, were not required to wear protective equipment to protect arms from contact with metal sparks.    Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.132 D01 I

Serious Gravity 5 3 instances 8 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.132(d)(1)(i):   The employer did not select, and have each affected employee use, the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment:    (a) Furnace Area, on or about November 14, 2012, and at times prior thereto, employees, fueling the furnace with metal scrap, were not required to wear protective equipment to protect arms from contact with metal sparks.    (b)  Pouring area, on or November 14, 2012, and at times prior thereto, employees assisting with the pouring of molten metal, were not required to wear fire retardant coveralls to protect them from molten metal splashes and back flashes from flames from off-gassing fires.    (c)  Outside, Scrap Metal Area, on or about October 10, 2012, and at times prior thereto, employees cutting up metal scrap, were not required to wear protective equipment to protect arms from contact with metal sparks.    Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 D01

Other-than-serious 1 instance 5 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.22(d)(1):  On every building or other structure, or part thereof, used for mercantile, business, industrial or storage purposes, the loads approved by the building official were not marked on plates of approved design and securely affixed in a conspicuous place in each space to which they relate.      (a)  Break Room ceiling, on or about October 10, 2012, and at times prior thereto, a load limit sign was not placed on the Break Room designating the load rating for storage on top of it.    Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.215 B09

Other-than-serious 1 instance 1 exposed
Issued
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.215(b)(9):  Guard for abrasive wheel machine where the operator stands in front of the machine was not constructed so that the peripheral protecting member could be adjusted to the constantly decreasing diameter of the wheel:      (a)   Machine Shop, on or about October 10, 2012, and at times prior thereto, the Baldor grinder (SN 604477WG92B, 3600 r.p.m.) was missing an adjustable tongue guard.        Note:  Abatement certification is NOT required for this item.  Item was corrected prior to monitoring on November 14, 2012.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.305 G01 I

Other-than-serious 1 instance 1 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(g)(1)(i):   Flexible cords and cables were not approved or conditions of use and location:      (a)   Heat Treat Furnace,  on or about October 10, 2012, and at times prior thereto, electrical extension cords used to power two 42" fans, were not all approved for outdoor use.      Note:  Abatement certification is required for this item.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View KITS FOUNDRY AND MACHINE, INC.'s full OSHA safety record →