Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: AKY CONSTRUCTION

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of AKY CONSTRUCTION in 6093 DEANSBORO DRIVE LOT 123, NEW ALBANY, OH 43054 (NAICS 238130). OSHA activity number 336830989.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch AKY Construction — free Get an email when a new federal OSHA severe-injury report for AKY Construction is published. One employer, no account, unsubscribe in one click.
Establishment
AKY CONSTRUCTION
Site address
6093 DEANSBORO DRIVE LOT 123
City
NEW ALBANY
State
OH
ZIP
43054
Mailing
5219 GODOWN ROAD BOX 217, COLUMBUS, OH 43235
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238130
Employees
3
Ownership type
A

7 citations on file for this inspection.

1926.403 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 17, 2012
Abate by
Oct 31, 2012
Penalty
Initial $1,600 · Current $560 Reduced
29 CFR 1926.403(b)(1)(i):     Suitability for installation and use in conformity with the provisions of this subpart. Suitability of equipment for an identified purpose may be evidenced by listing, labeling, or certification for that identified purpose.    a. On the east side of the jobsite, employees were using an indoor rated surge protector as an outdoor multi-plug extension cord, thereby exposing employees to a contact hazard.
Recent events (2)
  • — I (S) $560
  • — Z (S) $1600

1926.404 B01 III C

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 17, 2012
Abate by
Oct 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.404(b)(1)(iii)(C):     Each cord set, attachment cap, plug and receptacle of cord sets, and any equipment connected by cord and plug, except cord sets and receptacles which are fixed and not exposed to damage, shall be visually inspected before each day's use for external defects, such as deformed or missing pins or insulation damage, and for indications of possible internal damage. Equipment found damaged or defective shall not be used until repaired.    a. On the jobsite, employees were using extension cords with missing ground prongs, thereby exposing employees to a contact hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 A02 II J

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 17, 2012
Abate by
Oct 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(a)(2)(ii)(J):     Extension cord sets used with portable electric tools and appliances shall be of three-wire type and shall be designed for hard or extra-hard usage. Flexible cords used with temporary and portable lights shall be designed for hard or extra-hard usage.  NOTE: The National Electrical Code, ANSI/NFPA 70, in Article 400, Table 400-4, lists various types of flexible cords, some of which are noted as being designed for hard or extra-hard usage. Examples of these types of flexible cords include hard service cord (types S, ST, SO, STO) and junior hard service cord (types SJ, SJO, SJT, SJTO).    a. On the jobsite, employees were using extension cords that were not rated for hard or extra hard usage, thereby exposing employees to a contact hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.405 G02 IV

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 17, 2012
Abate by
Oct 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.405(g)(2)(iv):     Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.    a. On the jobsite, employees were using extension cords with missing ground prongs, thereby exposing employees to a contact hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.416 E01

Serious Gravity 5 1 instance 3 exposed
Issued
Oct 17, 2012
Abate by
Oct 31, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.416(e)(1):     Worn or frayed electric cords or cables shall not be used.    a. On the jobsite, employees were using extension cords that were worn and had frayed outer insulation, thereby exposing employees to a contact hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 17, 2012
Abate by
Oct 31, 2012
Penalty
Initial $2,000 · Current $700 Reduced
29 CFR 1926.501(b)(13):     "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502.    a. On the roof of the house, employees were installing roof sheeting without fall protection, thereby being exposed to a fall hazard.
Recent events (2)
  • — I (S) $700
  • — Z (S) $2000

1926.1053 B01

Serious Gravity 5 1 instance 1 exposed
Issued
Oct 17, 2012
Abate by
Oct 31, 2012
Penalty
Initial $2,000 · Current $700 Reduced
29 CFR 1926.1053(b)(1):     When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.    a. On the east side of the building, employees were using a ladder to access the roof that did not extend 3 feet above the roof, thereby being exposed to a fall hazard.
Recent events (2)
  • — I (S) $700
  • — Z (S) $2000

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336830989.