Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CONFLUENCE ENERGY, LLC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of CONFLUENCE ENERGY, LLC in 1809 HIGHWAY 9, KREMMLING, CO 80459 (NAICS 321999). OSHA activity number 336832787.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Confluence Energy, LLC — free Get an email when a new federal OSHA severe-injury report for Confluence Energy, LLC is published. One employer, no account, unsubscribe in one click.
Site address
1809 HIGHWAY 9
City
KREMMLING
State
CO
ZIP
80459
Mailing
P.O. BOX 1387, KREMMLING, CO 80459
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321999
Employees
28
Ownership type
A

8 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 5 instances 3 exposed
Issued
Mar 8, 2013
Abate by
Apr 12, 2013
Penalty
Initial $3,080 · Current $1,848 Reduced
OSH ACT of 1970 Section (5)(a)(1):  Section 5(a)(1) of the Occupational Safety and Health Act of 1970: Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to stuck by hazards associated with broken and or nonfunctioning material handling equipment.    (a)  Confluence Energy, 1809 Highway 9, Kremmling, CO: On or about October 11, 2012, the following hazards were noted on the Tigercat 240B log loader.     1) Two of the 6 overhead lights used during night operations were broken.  2) The horn to warn employees of approaching danger was nonfunctioning.  3) The operator cab window (side) to prevent dirt from entering the cab was missing.  4)  The step leading into the operators cab was substantially distorted creating a tripping hazard.   5) The grappler mechanism was not properly functioning. At times, the hydraulic pressure would lessen while suspending a load for unknown reasons. The unit continues to leak hydraulic fluid.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3080

1910.27 D02 II

Serious Gravity 5 2 instances 2 exposed
Issued
Mar 8, 2013
Abate by
Apr 12, 2013
Penalty
Initial $3,080 · Current $1,848 Reduced
29 CFR 1910.27(d)(2)(ii): Landing platforms were not equipped with standard railings and toeboards so arranged as to give safe access to and from the ladder. Platforms were not constructed of sufficient size to provide a safe access space of not less than 24 inches in width and 30 inches in length.    a)  Confluence Energy, LLC, 1809 Highway 9, Kremmling, CO:  Located at the top of the ladder used to access the airlock motor platform, employees are required to climb over guardrails installed between the ladder extensions.  Conditions exposed employees accessing the platform to a fall hazard of approximately 10 feet.    b)  Confluence Energy, LLC, 1809 Highway 9, Kremmling, CO: The platform used to support the dryer feed airlock motor was constructed without a minimum clear space of at least 24 inches in width and 30 inches in length. Condition exposed employees performing maintenance and/or servicing the airlock motor to a fall hazard of approximately 10 feet.    Abatement Note:  Abatement certification is required for this item (See enclosed Abatement-Certification Letter).
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3080

1910.27 D03

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 8, 2013
Abate by
Apr 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.27(d)(3): The side rails of through or side-step ladder extensions did not extend 3 1/2 feet above paraphets and landings:    a) Confluence Energy, LLC, 1809 Highway 9, Kremmling, CO.  Located at the top of the ladder used to access the airlock motor platform, one of the two ladder extensions was installed flush with the landing platform.  Condition exposed employees accessing the platform to a fall hazard of approximately 10 feet.    Abatement Note:  Abatement certification is required for this item (See enclosed Abatement-Certification Letter).
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.146 E01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 8, 2013
Abate by
Mar 27, 2013
Penalty
Initial $3,080 · Current $1,848 Reduced
29 CFR 1910.146(e)(1): Before entry was authorized, the employer did not document the completion of measures required by 29 CFR 1910.146(d)(3) by preparing an entry permit:    (a)  Confluence Energy, LLC, 1809 Highway 9, Kremmling, CO: The employer did not ensure established permit entry forms were completed prior to entering and cleaning the multi pass dryer drum. The employer has an established cleaning schedule requiring entry into the wood dryer drum on a weekly basis to remove accumulated wood residue (pitch).  The employers confined space programs identify the multi pass dryer drum as a permit required space.    Abatement Note:  Abatement certification is required for this item (See enclosed Abatement-Certification Letter).
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3080

1910.22 A01

Repeat Gravity 5 3 instances 28 exposed
Issued
Mar 8, 2013
Abate by
Apr 12, 2013
Penalty
Initial $6,160 · Current $3,696 Reduced
29 CFR 1910.22(a)(1): All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    (a)  Confluence Energy, LLC, 1809 Highway 9, Kremmling, CO: The employer had not developed and implemented a comprehensive housekeeping program to control the accumulation of fugitive combustible dust in and around the following areas:    1) Located around the outside dryer heater, windblown combustible dust accumulates against the hot dryer base. As a result of this condition, employees use flexible water hoses to extinguish fires that periodically occur. Condition expose employees to burn hazards associated with fire.    2) Located inside the pellet manufacturing building near the out-feed side of the rotating multi pass wood chip dryer, accumulation of combustible dust was allowed to accumulate on ledges and plastic wall insulation. Condition expose employees to burn hazards associated with fire.    3) Located inside the building at the bottom of the pellet dryer pit, the accumulation of combustible wood product was noted. Condition expose employees to burn hazards associated with fire.    Abatement Note:  Abatement certification is required for this item (See enclosed Abatement-Certification Letter).    Confluence Energy was previously cited for a violation of this Occupational Safety and health standard or its equivalent standard CFR 29 1910.22(a)(1) which was contained in OSHA inspection number 311908594, citation number 1, item number 2a, issued on January 20, 2009, with respect to a workplace located at 1809 Highway 9, Kremmling, CO.
Recent events (2)
  • — I (R) $3696
  • — Z (R) $6160

1910.132 D02

Other-than-serious 1 instance 28 exposed
Issued
Mar 8, 2013
Abate by
Apr 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, the identity of the workplace evaluated, the person certifying that the evaluation had been performed, and the date the hazard assessment was done:    (a)  Confluence Energy, LLC, 1809 Highway 9, Kremmling, CO: The employer had not developed a written certified document acknowledging the completion of a comprehensive hazard assessment of the workplace.     Abatement Note:  Abatement certification is required for this item (See enclosed Abatement-Certification Letter).    Abatement Note: The written certification must identify the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.    Abatement Note:  If the employer determines that hazards are or may be present, the employer shall implement the following:  1) Select, and have each affected employee use, the types of PPE that will protect the affected employee from the hazards identified in the hazard assessment;  2)  Communicate selection decisions to each affected employee; and,  3)  Select PPE that properly fits each affected employee. Note: Non-mandatory 1910.132 Appendix B contains an example of procedures that would comply with the requirement for a hazard assessment.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C06 I

Other-than-serious 6 instances 8 exposed
Issued
Mar 8, 2013
Abate by
Apr 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(6)(i): The employer did not conduct periodic inspection(s) of all energy control procedures at least annually to ensure that the procedure and the requirement of this standard were being followed:    a) Confluence Energy, LLC  Prior to October 11, 2012, the employer had not conducted annual review(s) of the employers written energy control procedures including but not limited to:  1) The multi pass dryer  2) Chipper  3) Hammer Mill  4) Pellet Mills\  5) 75 and 50 foot conveyor  6) Motor control station.    Abatement Note: The employer shall certify (in writing) that the periodic inspections above have been performed. The certification shall identify the machine or equipment on which the energy control procedure was being utilized, the date of the inspection, the employees included in the inspection, and the person performing the inspection.       Abatement Note: Per 29 CFR 1910.147( C )(6), the periodic inspection must determine that all topics listed in paragraphs [A] through [D] are being evaluated.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.147 C07 IV

Other-than-serious 1 instance 3 exposed
Issued
Mar 8, 2013
Abate by
Apr 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iv): The employer had not certified that employee training had been accomplished and kept up to date:    (a)  Confluence Energy, LLC, 1809 Highway 9, Kremmling, CO: The employer had not ensured appropriate training regarding energy isolation control/methods (lockout/tagout) was accomplished and kept up to date with records containing the name and date of training for each employee.     Abatement Note:  Abatement certification is required for this item (See enclosed Abatement-Certification Letter).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Confluence Energy, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336832787.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.