Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: VAN DEN HEUVEL ELECTRIC INC

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of VAN DEN HEUVEL ELECTRIC INC in 2851 UNIVERSITY AVE, GREEN BAY, WI 54311 (NAICS 238210). OSHA activity number 336836788.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch VAN DEN Heuvel Electric INC — free Get an email when a new federal OSHA severe-injury report for VAN DEN Heuvel Electric INC is published. One employer, no account, unsubscribe in one click.
Site address
2851 UNIVERSITY AVE
City
GREEN BAY
State
WI
ZIP
54311
Mailing
PO BOX 5787, DE PERE, WI 54115
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238210
Employees
29
Ownership type
A

5 citations on file for this inspection.

1926.20 B02

Deleted Serious Gravity 5 1 instance 25 exposed
Issued
Mar 5, 2013
Abate by
Apr 19, 2013
Penalty
Initial $4,200 · Current $0 Reduced
29 CFR 1926.20(b)(2):     The employer did not initiate and maintain a safety program which provides for frequent and regular inspections of jobsites, materials, and equipment to be made by a competent person:    a) Employer did not conduct work site inspections for safety and health hazards during new construction on a two (2) story commercial building.        ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4200

1926.21 B02

Other-than-serious 1 instance 1 exposed
Issued
Mar 5, 2013
Abate by
Apr 23, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.21(b)(2):     The employer did not instruct each employee in the recognition and avoidance of unsafe condition(s) and the regulation(s) applicable to his work environment to control or eliminate any hazard(s) or other exposure to illness or injury:    a) Employees were not instructed by the employer in safety procedures to testing wiring for voltage prior to working on the circuit.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED.
Recent events (2)
  • — I (O) $0
  • — Z (S) $0

1926.416 A01

Serious Gravity 10 1 instance 3 exposed
Issued
Mar 5, 2013
Abate by
Apr 23, 2013
Penalty
Initial $4,900 · Current $2,700 Reduced
29 CFR 1926.416(a)(1):     Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means:    a) On 10-03-12, employees who were installing permanent lighting fixtures in the ceiling grid and removing a temporary light cage off a permanent lighting whip in Area C of the Second Floor Lighting Plan, were in close proximity to an energized 277V Circuit Number 11.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED.
Recent events (2)
  • — I (S) $2700
  • — Z (S) $4900

1926.416 A03

Serious Gravity 10 1 instance 4 exposed
Issued
Mar 5, 2013
Abate by
Apr 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.416(a)(3):     When and where energized circuits existed, the employer failed to post and maintain proper warning signs, advise employees of the location, hazard involved and the proper protective measures to be taken:    a) On 10-03-12, employer did not use any means of warning employees in the work area of an energized 277V circuit Number 11 located in Area C of the Second Floor Lighting Plan; an employee did not test the circuit for voltage prior to removing a plastic cage temporary light from the energized circuit.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.417 A

Deleted Serious Gravity 10 1 instance 10 exposed
Issued
Mar 5, 2013
Abate by
Apr 19, 2013
Penalty
Initial $0 · Current $0
29 CFR 1926.417(a):     Controls that were to be de-activated during the course of work on energized or de-energized equipment or circuits were not tagged:    a) Employees, who worked inside the second floor panel room in Area C of the Lighting Plan to de-energize temporary light circuits, were using black electrical tape on the switches in place of tagging the closed circuit.    ABATEMENT CERTIFICATION AND ABATEMENT DOCUMENTATION REQUIRED.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View VAN DEN Heuvel Electric INC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336836788.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.