Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: KINEDYNE CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of KINEDYNE CORPORATION in 1104 WASHINGTON FERRY RD., PRATTVILLE, AL 36067 (NAICS 551114). OSHA activity number 336852181.

Watch Kinedyne Corporation — free Get an email when a new federal OSHA severe-injury report for Kinedyne Corporation is published. One employer, no account, unsubscribe in one click.
Site address
1104 WASHINGTON FERRY RD.
City
PRATTVILLE
State
AL
ZIP
36067
Mailing
1104 WASHINGTON FERRY RD, PRATTVILLE, AL 36067
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
551114
Employees
187
Ownership type
A

2 citations on file for this inspection.

5(a)(1)

Serious Gravity 5 1 instance 8 exposed
Issued
Abate by
Penalty
Initial $3600.00 · Current $3600.00
OSH ACT of 1970 Section (5)(a)(1): Section 5(a)(1) of the Occupational Safety and Health Act of 1970: The employer did not furnish employment and a place of employment which was free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to struck-by hazards from falling stock.    a) On or about October 16, 2012 and times prior in the warehouse: The employer failed to ensure damaged storage racks which had been struck at the base by forklifts, were repaired or that section of racks taken out of service until they could be repaired which exposed employees to the hazards associated with getting struck-by falling product and rack sections.
Recent events (2)
  • — I (S) $3600
  • — Z (S) $3600

1910.303 B01 VIII

Other-than-serious 1 instance 7 exposed
Issued
Abate by
Penalty
Initial $4500.00 · Current $0.00 Reduced
29 CFR 1910.303(b)(1)(viii): Safety of equipment was not determined using considerations for other factors which contributed to the practical safeguarding of employees using or likely to come in contact with the  equipment    a) On or about October 17, 2012 and times prior, the Wulftec Wrapper: The employer failed to ensure when employees were operating the Wulftec Wrapper Machine that they were protected from water leaking from the ceiling onto the equipment motors, electrical conductors or circuit parts which exposed them to electrical hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $4500

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336852181.