NORTH KINGSTOWN, RI —
OSHA Inspection: ALTHEA HOME IMPROVEMENTS
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of ALTHEA HOME IMPROVEMENTS in 100 INTREPID DR., NORTH KINGSTOWN, RI 02852 (NAICS 236116). OSHA activity number 336860390.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ALTHEA HOME IMPROVEMENTS
- Site address
- 100 INTREPID DR.
- City
- NORTH KINGSTOWN
- State
- RI
- ZIP
- 02852
- Mailing
- 543 PLAIN MEETING HOUSE RD., WEST GREENWICH, RI 02817
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 236116
- Employees
- 9
- Ownership type
- A
Citations
1 citation on file for this inspection.
1926.501 B13
- Issued
- Nov 5, 2012
- Penalty
- Initial $2,520 · Current $2,520
General-duty citation text
29 CFR 1926.501(b)(13): "Residential construction." Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels shall be protected by guardrail systems, safety net system, or personal fall arrest system unless another provision in paragraph (b) of this section provides for an alternative fall protection measure. Exception: When the employer can demonstrate that it is infeasible or creates a greater hazard to use these systems, the employer shall develop and implement a fall protection plan which meets the requirements of paragraph (k) of 1926.502. Note: There is a presumption that it is feasible and will not create a greater hazard to implement at least one of the above-listed fall protection systems. Accordingly, the employer has the burden of establishing that it is appropriate to implement a fall protection plan which complies with 1926.502(k) for a particular workplace situation, in lieu of implementing any of those systems. Worksite: Employees working on the roof of a new residential home were not provided with proper fall protection.
Recent events (1)
- — Z (S) $2520
More inspections in this industry (NAICS 236116)
More inspections in RI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336860390.