Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: SYSTEMS ENGINEERING T/A MIDAS

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of SYSTEMS ENGINEERING T/A MIDAS in 1620 RHODE ISLAND AVENUE, NE, WASHINGTON, DC 20018 (NAICS 811111). OSHA activity number 336863584.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Systems Engineering T/A Midas — free Get an email when a new federal OSHA severe-injury report for Systems Engineering T/A Midas is published. One employer, no account, unsubscribe in one click.
Site address
1620 RHODE ISLAND AVENUE, NE
City
WASHINGTON
State
DC
ZIP
20018
Mailing
1620 RHODE ISLAND AVENUE, NE, WASHINGTON, DC 20018
Inspection type
Complaint (B)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811111
Employees
36
Ownership type
A

20 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 3 instances 4 exposed
Issued
Jan 11, 2013
Abate by
Jan 31, 2013
Penalty
Initial $4,900 · Current $4,900
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to workers, in that employees were exposed to struck by and crushing hazards while working under defective automotive lifts:    a) Auto Repair Shop Lift Number 1 - On or about October 11, 2012, an employee was observed standing below a vehicle raised overhead on an in-ground two post hydraulic vehicle lift where visible hydraulic oil was seeping from the floor at the base of the left lifting post, lift pads were badly worn, and there were no functioning lift locks for either lift post, exposing employees to a struck by and or crushing hazard.    b) Auto Repair Shop Lift Number 3 -  On or about October 11, 2012, an employee was observed standing below a vehicle raised overhead on an Ammco two post surface mounted hydraulic vehicle lift where the left lifting post lift lock was inoperable due to a broken cable, the lift pads were badly worn, the lift swing arm restraints were not functioning, and there was no top center support provided, exposing the employees to a struck by and or crushing hazard.    c) Auto Repair Shop Lift Number 4 - On or about October 11, 2012, an employee was observed standing below a vehicle raised overhead on a Challenger model number E10, serial number 0911000000054298, two post surface mounted hydraulic vehicle lift, and the left post suspension wire rope was showing slack, exposing the employee to a struck by and or crushing hazard.        ABATEMENT DOCUMENTATION REQUIRED
Recent events (2)
  • — C (S) $4900
  • — Z (S) $4900

1910.24 F

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 11, 2013
Abate by
Jan 22, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.24(f): Rise height and tread width were not uniform throughout any flight of stairs including any foundation structure used as one or more treads of the stairs:    a) Shop Area - An employee was observed using a fix stairway to gain access to an upstairs storage area, and one side of a stair tread was broken loose from the stringer causing a trip and fall hazard.
Recent events (2)
  • — C (S) $2800
  • — Z (S) $2800

1910.132 D01

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jan 11, 2013
Abate by
Jan 22, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.132(d)(1): The employer did not assess the workplace to determine if hazards are present, or are likely to be present, which necessitate the use of personal protective equipment (PPE):    a) Shop Area - A hazard assessment was not conducted as evidenced by noted hazards such as but not limited to; an employee using a pneumatic lug wrench while removing tire lugs, not wearing eye protection, an employee cutting a sway bar from an automobile using a Bosch saws-all, model #R535, not wearing eye protection, employee pulling an oil pan plug while standing below not wearing eye protection, and employees standing below raised automobiles, removing overhead parts not wearing head protection.
Recent events (3)
  • — F (S) $0
  • — C (S) $3500
  • — Z (S) $3500

1910.133 A01

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jan 11, 2013
Abate by
Jan 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(1): The employer did not ensure that each affected employee uses appropriate eye or face protection when exposed to eye or face hazards from flying particles, molten metal, liquid chemicals, acids or caustic liquids, chemical gases or vapors, or potentially injurious light radiation:    a) Shop Area at Lift #1 - An employee was observed cutting a steel sway bar using a Bosch saw, model #R535, and not wearing eye protection.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.133 A03

Deleted Serious Gravity 5 1 instance 1 exposed
Issued
Jan 11, 2013
Abate by
Jan 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.133(a)(3): The employer did not ensure that each affected employee who wore prescription lenses while engaged in operations that involved eye hazards wore eye protection that incorporated the prescription in its design, or wore eye protection that could be worn over the prescription lenses without disturbing the proper position of the prescription lenses or the protective lenses:     a) Shop Area at Lift #4 - An employee was observed standing under a vehicle removing an oil pan lug bolt to drain oil, and wearing only prescription glasses.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.135 A

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jan 11, 2013
Abate by
Jan 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.135(a): The employer did not ensure that each affected employee wore a protective helmet when working in areas where there was a potential for injury to the head from falling objects:     a) Shop Area - Employees were observed standing underneath elevated vehicles while performing repair work and not wearing head protection.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.215 A04

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 11, 2013
Abate by
Jan 17, 2013
Penalty
Initial $2,800 · Current $2,800
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one eighth inch:    a) Shop Area - Employee was using a Ryobi bench grinder to remove a burr from a piece of pipe, and the tool rest was one half inch from the face of the stone, on or about 10/11/12.
Recent events (2)
  • — C (S) $2800
  • — Z (S) $2800

1910.215 B09

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 11, 2013
Abate by
Jan 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:    a) Shop Area - Employee was using a Ryobi bench grinder to remove a burr from a piece of pipe, and the tongue guard was two and a half inches from the face of the stone, on or about 10/11/12.
Recent events (2)
  • — C (S) $0
  • — Z (S) $0

1910.253 B02 II

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jan 11, 2013
Abate by
Jan 17, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 feet (6.1 m) from highly combustible materials such as oil or excelsior:    a) Shop Area - Three acetylene cylinders were being stored within a foot of a 30 gallon container of motor oil.
Recent events (3)
  • — F (S) $0
  • — C (S) $2800
  • — Z (S) $2800

1910.253 B02 IV

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 11, 2013
Abate by
Jan 17, 2013
Penalty
Initial $0 · Current $2,800
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinders were designed to accept caps, were not always in place, hand-tight, except when cylinders were in use or connected for use:    a) Shop Area - An acetylene cylinder was being stored and the valve cap was missing.
Recent events (3)
  • — F (S) $2800
  • — C (S) $0
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 11, 2013
Abate by
Jan 17, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet:    a) Shop Area - Three oxygen and three acetylene cylinders were stored together.
Recent events (2)
  • — C (S) $0
  • — Z (S) $0

1910.303 B02

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 11, 2013
Penalty
Initial $3,500 · Current $3,500
29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling:    a) Storage Area - NM #14 wiring was used to supply power to an exterior sign, and the splices were not in junction boxes, protected from physical damage, 110 volt service.
Recent events (2)
  • — C (S) $3500
  • — Z (S) $3500

1910.303 B08

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 11, 2013
Abate by
Jan 17, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.303(b)(8): Electric equipment was not firmly secured to the surface on which it was mounted:    a) Shop Area - Employees were using a duplex electrical outlet that was hanging by its conductors and supplying power to a FMC Computer Wheel Balancer model #418, 110 volt, 15 amp service.
Recent events (3)
  • — F (S) $0
  • — C (S) $3500
  • — Z (S) $3500

1910.303 F02

Serious Gravity 5 1 instance 5 exposed
Issued
Jan 11, 2013
Abate by
Feb 15, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:    a) Electric Closet - Circuit breakers in two service panels were not labeled, 110 volt, 100 amp service.
Recent events (3)
  • — F (S) $0
  • — C (S) $3500
  • — Z (S) $3500

1910.303 G01 II

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 11, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1)(ii): The required working space about electric equipment rated 600 volts, nominal, or less to ground, was used for storage:    a) Electric Closet - A 55 gallon barrel filled with dirty shop clothes and a metal dolley covered in shop clothes were stored in front of two electrical service panels.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.304 G05

Serious Gravity 5 2 instances 4 exposed
Issued
Jan 11, 2013
Abate by
Jan 22, 2013
Penalty
Initial $3,500 · Current $3,500
29 CFR 1910.304(g)(5): The path to ground from circuits, equipment, and enclosures was not permanent, continuous, and effective:    a) Shop Area - Employees were using #1 Ammco brake lathe to turn brake rotors and the plug was missing the ground pin, 110 volt, on or about 10/11/12.    b) Shop Area - An employee were observed using #2 Ammco brake lathe to turn a brake rotor and the plug was missing the ground pin, 110 volt.
Recent events (2)
  • — C (S) $3500
  • — Z (S) $3500

1910.305 B01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 11, 2013
Abate by
Jan 21, 2013
Penalty
Initial $3,500 · Current $0 Reduced
29 CFR 1910.305(b)(1)(i): Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed:    a) Shop Area - Employee was using a duplex electrical outlet to provide power to an FMC Computer Wheel Balancer, and the conduit containing electrical conductors was pulled away from the outlet box, leaving  an opening, 110 volt, 15 amp service.
Recent events (3)
  • — F (S) $0
  • — C (S) $3500
  • — Z (S) $3500

1910.305 B01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 11, 2013
Abate by
Jan 21, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    a) Shop Area - An employee was observed using an FMC Computer Wheel Balancer and the electrical outlet supplying power was missing a knock out on the back of the box, 110 volt, 15 amp service.
Recent events (3)
  • — F (S) $0
  • — C (S) $0
  • — Z (S) $0

1910.1200 G01

Deleted Serious Gravity 5 1 instance 4 exposed
Issued
Jan 11, 2013
Abate by
Jan 22, 2013
Penalty
Initial $2,800 · Current $0 Reduced
29 CFR 1910.1200(g)(1):  Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use:    a) Shop Area - An employee was observed adding Larco re-manufactured anti-freeze, and a material safety data sheet was not available.
Recent events (3)
  • — F (S) $0
  • — C (S) $2800
  • — Z (S) $2800

1910.1200 H01

Other-than-serious 1 instance 4 exposed
Issued
Jan 11, 2013
Abate by
Feb 15, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area:    a) Shop Area - An employee was observed pouring Larco re-manufactured anti-freeze into a vehicle, and had not received hazard communication training.
Recent events (3)
  • — F (O) $0
  • — C (S) $0
  • — Z (S) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336863584.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.