WAILUKU, HI —
OSHA Inspection: CAMPOS AUTO BODY AND TOWING
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CAMPOS AUTO BODY AND TOWING in 1191 LOWER MAIN STREET, WAILUKU, HI 96793 (NAICS 811121). OSHA activity number 336872189.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- CAMPOS AUTO BODY AND TOWING
- Site address
- 1191 LOWER MAIN STREET
- City
- WAILUKU
- State
- HI
- ZIP
- 96793
- Mailing
- 1191 LOWER MAIN STREET, WAILUKU, HI 96793
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 811121
- Employees
- 15
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.101 B
- Issued
- Dec 3, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1910.101(b): The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks were not in accordance with Compressed Gas Association Pamphlet P-1-1965, which was incorporated by reference as specified in 29 CFR 1910.6: Compressed gas cylinders located in the vehicle servicing area were not secured.
Recent events (1)
- — Z (S) $2000
1904.4 B
- Issued
- Dec 3, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $400 · Current $400
General-duty citation text
29 CFR 1904.4(a): The employer did not record each work-related fatality, injury or illness case that resulted in the general recording criteria on the OSHA Form 300 or equivalent. Employer has never maintained OSHA 300 logs or equivalent.
Recent events (1)
- — Z (O) $400
1910.157 C01
- Issued
- Dec 3, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(c)(1): Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries: The designated portable fire extinguisher, located in the office area on the west wall, was sitting on the floor and not mounted in its holder located on the wall.
Recent events (1)
- — Z (O) $0
1910.157 E03
- Issued
- Dec 3, 2012
- Abate by
- Dec 13, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.157(e)(3): Portable fire extinguishers were not subjected to an annual maintenance check: The portable ABC fire extinguisher, located in the lobby or main office area, had not been inspected since 2010.
Recent events (1)
- — Z (O) $0
More inspections in this industry (NAICS 811121)
More inspections in HI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336872189.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.