KAPOLEI, HI —
OSHA Inspection: PACIFIC PALLET, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PACIFIC PALLET, INC. in 91-466 KOMOHANA ST., KAPOLEI, HI 96707 (NAICS 321920). OSHA activity number 336876180.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PACIFIC PALLET, INC.
- Site address
- 91-466 KOMOHANA ST.
- City
- KAPOLEI
- State
- HI
- ZIP
- 96707
- Mailing
- 91-466 KOMOHANA ST., KAPOLEI, HI 96707
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 321920
- Employees
- 12
- Ownership type
- A
Citations
10 citations on file for this inspection.
1910.212 A01
- Issued
- Nov 6, 2012
- Abate by
- Feb 28, 2013
- Penalty
- Initial $2,800 · Current $1,960 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: a) Employees were exposed to laceration and amputation hazards when operating the horizontal band saw to dismantle pallets. b) Employees operating the green stacking machine were not protected from hazards created by the rotating shaft and conveyor nip points. The employer did not assure that a rotating shaft and in-going nip points, located at the discharge end of the chain conveyor, were guarded. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1960
- — Z (S) $2800
1910.213 A09
- Issued
- Nov 6, 2012
- Abate by
- Nov 27, 2012
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.213(a)(9): All belts, pulleys, gears, shafts, and moving parts were not guarded in accordance with the specific requirements of 1910.219: a) The employer did not assure the belt and pulleys, which transfer power from the trim track saw motor to the saw, were guarded. Employees were exposed to hazards created by the rotating parts and nip-points. b) Employees were exposed to in-running nip-points and moving parts hazards of the trim track saw. The employer did not assure that ingoing nip-points of the conveyor track, and of the chain and sprocket used to transfer power from the conveyor motor to the conveyor track, were guarded to protect employees from injury. c) The employer did not assure that a portion of the saw blade, located behind the table, was guarded to protect employees from amputation injury. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1910.219 D01
- Issued
- Nov 6, 2012
- Abate by
- Nov 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o): a) The employer did not assure that pulleys that transferred power from the green stacker motor to the conveyor were guarded. Employees were exposed to hazards created by the rotating parts and nip-points. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.219 E03 I
- Issued
- Nov 6, 2012
- Abate by
- Nov 27, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.219(e)(3)(i): Vertical or inclined belt(s) were not enclosed by guard(s) conforming to the requirements specified at 29 CFR 1910.219(m) and (o) a) The employer did not assure that the inclined belt that transfers power from the stacker motor to the conveyor was guarded. Employees were exposed to hazards created by the rotating parts and nip-points. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.303 B01
- Issued
- Nov 6, 2012
- Abate by
- Dec 4, 2012
- Penalty
- Initial $2,000 · Current $1,400 Reduced
General-duty citation text
29 CFR 1910.303(b)(1): Electrical equipment was not free from recognized hazards that were likely to cause death or serious physical harm to employees: a) On or about October 16, 2012, the employer did not assure that the electrical enclosure box and associated power receptacle of the green stacker was free from electrical hazards by ensuring that the equipment was in good repair and located so as not to be damaged from weather. Employees were exposed to electrical hazards in that the disconnect box and associated power receptacle were damaged and a flexible cord was exposed to abrasion in that it was not protected from a moving drive belt. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1400
- — Z (S) $2000
1910.303 B07 I
- Issued
- Nov 6, 2012
- Abate by
- Dec 4, 2012
- Penalty
- Initial $1,600 · Current $1,120 Reduced
General-duty citation text
29 CFR 1910.303(b)(7)(i): Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment: a) The employer did not assure that an unused opening of an electrical box was effectively closed. The electrical box located inside the building in the storage area and used to supply power to the green stacker machine, exposed employees to a 480 volt electrical hazard. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $1120
- — Z (S) $1600
1910.305 D02
- Issued
- Nov 6, 2012
- Abate by
- Dec 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(d)(2): Panelboards were not mounted in cabinets, cutout boxes, or enclosures approved for the purpose and were not dead front: a) Employees were exposed to electrical hazards in that a panelboard mounted in a cabinet and used to power the green stacker machine was not dead front. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1904.29 A
- Issued
- Nov 6, 2012
- Abate by
- Feb 28, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1904.29(a): The employer did not use an OSHA 300, 301 and 300A Form or equivalent. a) The employer did not meet the basic requirements for recording injuries and illnesses. OSHA forms 300 were not maintained for calendar year 2012. In June of 2012 the company experienced a recordable injury that resulted in days away from work. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.303 G01
- Issued
- Nov 6, 2012
- Abate by
- Nov 19, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment: a) The employer did not assure that access to the 480 volt electrical panel was maintained with at least three feet clear space. The area in front of the electrical equipment located in the garage, was blocked by a shelving unit directly in front of the panel, hindering an employee's ability to access the equipment. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.305 G01 IV B
- Issued
- Nov 6, 2012
- Abate by
- Dec 11, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.305(g)(1)(iv)(B): Flexible cords and cables were run through holes in walls, ceilings, or floors: a) Flexible cords and cables used to power equipment such as, but not limited to, the green stacker were run through openings through walls and ceilings. In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Pacific Pallet, INC.
View Pacific Pallet, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 321920)
More inspections in HI
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336876180.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.