BROWNSVILLE, TX —
OSHA Inspection: PEDERSON CONSTRUCTION COMPANY, INCORPORATED
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of PEDERSON CONSTRUCTION COMPANY, INCORPORATED in W. JEFFERSON ST, BROWNSVILLE, TX 78520 (NAICS 237110). OSHA activity number 336881586.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PEDERSON CONSTRUCTION COMPANY, INCORPORATED
- Site address
- W. JEFFERSON ST
- City
- BROWNSVILLE
- State
- TX
- ZIP
- 78520
- Mailing
- 806 W OCEAN BLVD, LOS FRESNOS, TX 78566
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 237110
- Employees
- 25
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.21 B02
- Issued
- Nov 7, 2012
- Abate by
- Dec 5, 2012
- Penalty
- Initial $1,800 · Current $0 Reduced
General-duty citation text
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: At this excavation site, employees were not trained in the following: A. Employees who were required to enter and work in trenches and excavations were not trained in how to recognize hazardous conditions. B. The employer had not designated and trained a person to be a competent person for trenching and excavation operations.
Recent events (2)
- — I (S) $0
- — Z (S) $1800
1926.404 F06
- Issued
- Nov 7, 2012
- Penalty
- Initial $1,530 · Current $1,250 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: At this excavation site, employees utilized an extension cord to energize a hammer drill which was missing its ground pin. Employees were exposed to electrical shock and burns.
Recent events (2)
- — I (S) $1250
- — Z (S) $1530
1926.651 C02
- Issued
- Nov 7, 2012
- Penalty
- Initial $1,530 · Current $1,250 Reduced
General-duty citation text
29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: At this excavation site, employees entered a vertical wall trench which was over 9 feet deep by 14 feet wide by 30 feet in length to install a 36 inch storm drain pipe. There was no ladder in the trench for egress from the trench.
Recent events (2)
- — I (S) $1250
- — Z (S) $1530
1926.652 A01
- Issued
- Nov 7, 2012
- Penalty
- Initial $2,400 · Current $2,000 Reduced
General-duty citation text
29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652(c). At this excavation site, an employee installing rebar into the storm drain pipe worked between the junction box and the southwest dirt wall. The employee was exposed to hazards associated with a trench collapse.
Recent events (2)
- — I (S) $2000
- — Z (S) $2400
1926.51 A04
- Issued
- Nov 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.51(a)(4): The common drinking cup was not prohibited. At this excavation site, the employer did not ensure drinking cups were provided to prevent the drinking of water from various containers. The employees drank water from re-used soda bottles.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1926.405 G02 IV
- Issued
- Nov 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: At this excavation site, an extension cord utilized to energize a hammer drill did not have strain relief.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Pederson Construction Company, Incorporated
View Pederson Construction Company, Incorporated's full OSHA safety record →
More inspections in this industry (NAICS 237110)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336881586.