BENSENVILLE, IL —
OSHA Inspection: IRMKO TOOL WORKS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of IRMKO TOOL WORKS, INC. in 205 PARK STREET, BENSENVILLE, IL 60106 (NAICS 332710). OSHA activity number 336882394.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- IRMKO TOOL WORKS, INC.
- Site address
- 205 PARK STREET
- City
- BENSENVILLE
- State
- IL
- ZIP
- 60106
- Mailing
- 205 PARK STREET, BENSENVILLE, IL 60106
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332710
- Employees
- 28
- Ownership type
- A
Citations
6 citations on file for this inspection.
1910.212 A01
- Issued
- Mar 27, 2013
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks: Grinding/Polishing Room. The belt sander (Mfr. Charles L'Hommedieu & son) did not have a guard to protect employees from the ingoing nip points created by the pulley and belt on the sander. There is no abatement documentation or certification required for this item.
Recent events (2)
- — I (S) $1487.5
- — Z (S) $2975
1910.305 B01 II
- Issued
- Mar 27, 2013
- Penalty
- Initial $1,785 · Current $893 Reduced
General-duty citation text
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed. Automatic Band Saw Area. The energized electrical disconnect box (110v) on the wall behind the horizontal bandsaw had an uncovered opening on the side from a missing knockout. There is no abatement documentation or certification required for this item.
Recent events (2)
- — I (S) $892.5
- — Z (S) $1785
1910.334 C01
- Issued
- Mar 27, 2013
- Abate by
- May 13, 2013
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.334(c)(1): Unqualified persons performed testing work on electric circuits or equipment. Maintenance employee(s) who performed voltage testing on energized components up to 240v on machines such as, but not limited to, grinders and mills, were not qualified to perform testing work on electric circuits or equipment. Abatement certification is required for this item in accordance with 29 CFR 1903.19(c). Abatement note: Qualified persons shall be capable of working safely on energized circuits and shall be familiar with the proper use of special precautionary techniques, personal protective equipment (PPE), insulating & shielding materials and insulated tools (see 1910.333(c)(2)).
Recent events (2)
- — I (S) $1487.5
- — Z (S) $2975
1910.335 A01 I
- Issued
- Mar 27, 2013
- Abate by
- May 1, 2013
- Penalty
- Initial $2,975 · Current $1,488 Reduced
General-duty citation text
29 CFR 1910.335(a)(1)(i): Employees working in areas where there were potential electrical hazards were not provided with electrical protective equipment that was appropriate for the specific parts of the body that needed to be protected and for the work being performed: Maintenance employee(s) performed voltage testing on energized components up to 240v on machines such as, but not limited to, grinders, and mills. Electrical protective equipment was not provided or utilized, including but not limited to the following, to protect against electrical shock and arc flash/blast injuries: a) Rubber insulating gloves with leather protectors. b) Arc-rated long-sleeve shirt and pants or arc-rated coverall. c) Hearing protection (canal inserts). Abatement certification is required for instance b) only in accordance with 29 CFR 1903.19(c). Instances a) and c) were corrected during inspection. Abatement Note: For compliance assistance, refer to NFPA 70E national consensus standard "Standard for Electrical Safety in the Workplace, 2012 Edition", www.NFPA.org.
Recent events (2)
- — I (S) $1487.5
- — Z (S) $2975
1910.335 A01 IV
- Issued
- Mar 27, 2013
- Abate by
- May 1, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(iv): Employees exposed to the danger of head injury from electric shock or burns due to contact with exposed energized parts did not wear nonconductive head protection: Maintenance employee(s) performed voltage testing on energized components up to 240v. Nonconductive head protection was not worn. Abatement certification is required for this item in accordance with the requirements of 29 CFR 1903.19(c). Abatement Note: For compliance assistance, refer to NFPA 70E national consensus standard "Standard for Electrical Safety in the Workplace, 2012 Edition", www.NFPA.org.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.335 A01 V
- Issued
- Mar 27, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.335(a)(1)(v): Employees exposed to the danger of injury to the eyes or face from electric arcs or flashes or from flying objects resulting from electrical explosion did not wear protective equipment for the eyes or face: Maintenance employee(s) performed voltage testing on energized components up to 240v. A face shield was not worn to protect the eyes and face from electric arcs or flashes or from flying debris. There is no abatement documentation or certification required for this item. Abatement note: For compliance assistance, refer to NFPA 70E national consensus standard "Standard for Electrical Safety in the Workplace, 2012 Edition", www.NFPA.org.
Recent events (2)
- — I (S) $0
- — Z (S) $0
More inspections in this industry (NAICS 332710)
More inspections in IL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336882394.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.