Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: R&S UNITED SERVICES, INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of R&S UNITED SERVICES, INC. in 15 RANICK DRIVE WEST, AMITYVILLE, NY 11701 (NAICS 238220). OSHA activity number 336899182.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch R&S United Services, INC. — free Get an email when a new federal OSHA severe-injury report for R&S United Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
15 RANICK DRIVE WEST
City
AMITYVILLE
State
NY
ZIP
11701
Mailing
15 RANICK DRIVE WEST, AMITYVILLE, NY 11701
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238220
Employees
30
Ownership type
A

6 citations on file for this inspection.

1910.1052 D01 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 5, 2013
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.1052(d)(1)(i):   Where methylene chloride was present in the workplace, the employer did not determine each employee's exposure by taking personal breathing zone air samples or taking personal breathing zone air samples that are representative of each employee's exposure:    a) Shop area - Employees use a product called "MEI Eco-Canister System Adhesive 22-18" which contains 40 - 50% Methylene Chloride to glue insulation onto ductwork.  The employer did not determine each employee's exposure to methylene chloride by taking personal breathing zone air samples or representative personal breathing zone air samples; on or about 2/28/13.    Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.1052 F03 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 5, 2013
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.1052(f)(3)(i):     The employer did not implement procedures to detect leaks of methylene chloride in the workplace and did not make provisions to contain any spills and to safely dispose of any methylene chloride contaminated waste materials:    a) Shop Area - Employees use a product called "MEI Eco-Canister System Adhesive 22-18" which contains 40 - 50% Methylene Chloride to glue insulation onto ductwork.  The employer did not implement procedures to detect and contain methylene chloride leaks in the workplace.  The employer did not provide safe means to dispose of methylene chloride waste materials, on or about 2/28/13.    Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.1052 G03 I

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 5, 2013
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.1052(g)(3)(i):     The employer did not select and provide to employees, the appropriate atmosphere-supplying respirator specified in 29 CFR 1910.134(d)(3)(i)(A) and selected or used half masks:    a) Shop area - Employees use a product called "MEI Eco-Canister System Adhesive 22-18" which contains 40 - 50% Methylene Chloride to glue liner onto ductwork.  The employer provided employees with dust masks and not an appropriate atmosphere-supplying respirator when using this product; on or about 2/28/13.    Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.1052 H01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1052(h)(1):     Where needed to prevent methylene chloride induced skin or eye irritation, the employer did not provide clean protective clothing and equipment resistant to methylene chloride, at no cost to the employee, and/or did not ensure that each affected employee used it:    a) Shop area - Employees use a product called "MEI Eco-Canister System Adhesive 22-18" which contains 40 - 50% Methylene Chloride to glue insulation onto ductwork.  The employees wore canvas gloves when handling methylene chloride and were not provided with appropriate personal protective equipment that is impervious to methylene chloride; on or about 2/28/13.    Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1052 K01 II

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 5, 2013
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.1052(k)(1)(ii):     The employer did not communicate the following hazards associated with methylene chloride on labels and in material safety data sheets in accordance with the requirements of the Hazard Communication Standard 29 CFR 1910.1200, 29 CFR 1915.1200, or 29 CFR 1926.59 as appropriate: cancer, cardiac effects (including elevation of carboxyhemoglobin), central nervous system effects, liver effect, and skin and eye irritation:    a) Shop Area - Employees use a product called "MEI Eco-Canister System Adhesive 22-18" which contains 40 - 50% Methylene Chloride to glue insulation onto ductwork.  The employer did not communicate the health hazards associated with methylene chloride to the affected employees, on or about 2/28/13.    Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.1052 L01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 5, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.1052(l)(1):     The employer did not provide information and training for each affected employee prior to or at the time of initial assignment to a job involving potential exposure to methylene chloride:    a) Shop Area - Employees use a product called "MEI Eco-Canister System Adhesive 22-18" which contains 40 - 50% Methylene Chloride to glue insulation onto ductwork.  The employer did not provide appropriate information and training on methylene chloride prior to or at the time of assignment for affected employees; on or about 2/28/13.    Note:   Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View R&S United Services, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336899182.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.