FREWSBURG, NY —
OSHA Inspection: SCANLON ERECTORS, INC.
Unprogrammed Other inspection · Safety discipline
At a glance
On , OSHA opened an unprogrammed Other safety inspection of SCANLON ERECTORS, INC. in 1715 WHALGREN ROAD, FREWSBURG, NY 14738 (NAICS 238120). OSHA activity number 336900980.
Where did this inspection happen?
- Establishment
- SCANLON ERECTORS, INC.
- Site address
- 1715 WHALGREN ROAD
- City
- FREWSBURG
- State
- NY
- ZIP
- 14738
- Mailing
- 2793 CONVENTRY GREEN, HAMBURG, NY 14075
What kind of inspection was it?
- Inspection type
- Unprogrammed Other (I)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- A
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238120
- Employees
- 4
- Ownership type
- A
Citations
2 citations on file for this inspection.
1926.404 B01 I
- Issued
- Penalty
- Initial $1200.00 · Current $900.00 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) On or about 10/17/12 at the Frewsburg Water District Well #5 project located at 1715 Wahlgren Road, Frewsburg, New York; employees were using a Dewalt screw gun to attach steel flashing pieces. The screw gun was plugged into an extension cord that went to a receptacle that was not protected by a ground fault circuit interrupter and there was no assured equipment grounding conductor program in place. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $900
- — Z (S) $1200
1926.502 B01
- Issued
- Penalty
- Initial $1600.00 · Current $1200.00 Reduced
General-duty citation text
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level: a) On or about 10/17/12 at the Frewsburg Water District Well #5 project located at 1715 Wahlgren Road, Frewsburg, New York; the side walls of a new concrete tank, that was 8 feet deep, were only 29" above grade. NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1200
- — Z (S) $1600
More inspections at SCANLON ERECTORS, INC.
JAMESTOWN, NY—2007-08-10 00:00:00
SCANLON ERECTORS, INC.
NIAGARA FALLS, NY—2007-04-27 00:00:00
SCANLON ERECTORS, INC.
CANANDAIGUA, NY—2007-01-23 00:00:00
SCANLON ERECTORS, INC
BUFFALO, NY—2007-01-12 00:00:00
SCANLON ERECTORS, INC.
WEBSTER, NY—2005-06-13 00:00:00
SCANLON ERECTORS, INC.
View SCANLON ERECTORS, INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238120)
EL PASO, TX—2026-07-15
SURE STEEL
NAMPA, ID—2026-07-15
ELITE STEEL ERECTORS, LLC
GARDENDALE, AL—2026-07-09
ANDINO'S IRON WORKERS, LLC
MIDLOTHIAN, VA—2026-07-09
B & J STEEL CONSTRUCTION, INC.
LYNCHBURG, VA—2026-07-09
GRAY'S WELDING LLC
More inspections in NY
MAYVILLE, NY—2026-07-16
MAYVILLE VILLAGE DPW
NEW HYDE PARK, NY—2026-07-16
NORTH HEMPSTEAD TN MICHAEL J TULLY PARK
CONESUS, NY—2026-07-16
CONESUS TN HIGHWAY DEPT
COMSTOCK, NY—2026-07-15
NYSDOCCS WASHINGTON CORRECTIONAL FACILITY
BALDWINSVILLE, NY—2026-07-15
LYSANDER TOWN HIGHWAY DEPARTMENT
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336900980.