NIAGARA FALLS, NY —
OSHA Inspection: NIAGARA METALS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of NIAGARA METALS LLC in 4861 PACKARD ROAD, NIAGARA FALLS, NY 14304 (NAICS 423930). OSHA activity number 336904990.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- NIAGARA METALS LLC
- Site address
- 4861 PACKARD ROAD
- City
- NIAGARA FALLS
- State
- NY
- ZIP
- 14304
- Mailing
- P.O. BOX 3116, NIAGARA FALLS, NY 14304
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 20
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.147 C04 II
- Issued
- Oct 22, 2012
- Abate by
- Dec 31, 2012
- Penalty
- Initial $2,975 · Current $2,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(4)(ii): Procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, 29 CFR 1910.147(c)(4)(ii)(C): Specific procedural steps for the placement, removal and transfer of lockout devices or tagout devices and the responsibility for them; and a) On or about 10/17/2012 throughout establishment; where the employer's energy control procedures did not include specific, documented procedures for removal of lockout devices by other than the employee who applied the device. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $2000
- — Z (S) $2975
1910.178 L04 III
- Issued
- Oct 22, 2012
- Abate by
- Dec 31, 2012
- Penalty
- Initial $2,380 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not conducted at least once every three years. a) On or about 10/17/2012 throughout yard and production areas; where the last documented driver evaluation for powered industrial drivers was in 2007. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (S) $1000
- — Z (S) $2380
1910.147 C06 I
- Issued
- Oct 22, 2012
- Abate by
- Dec 31, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(6)(i): The employer did not conduct a periodic inspection of the energy control procedures at least annually to ensure that the procedures and the requirements of this standard are being followed: a) On or about 10/17/2012 throughout establishment; where employees perform activities covered by the energy control standard, the annual inspection was not conducted. ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at Niagara Metals LLC
View Niagara Metals LLC's full OSHA safety record →
More inspections in this industry (NAICS 423930)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336904990.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.