LANCASTER, TX —
OSHA Inspection: CANDELARIO MORALES ALVAREZ
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of CANDELARIO MORALES ALVAREZ in 1005 PLEASANT RUN, LANCASTER, TX 75146 (NAICS 238140). OSHA activity number 336927587.
Where did this inspection happen?
- Establishment
- CANDELARIO MORALES ALVAREZ
- Site address
- 1005 PLEASANT RUN
- City
- LANCASTER
- State
- TX
- ZIP
- 75146
- Mailing
- 3103 CROSSMAN AVE., DALLAS, TX 75212
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 2
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.100 A
- Issued
- Abate by
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets. This violation occurred on October 18, 2012, at a workplace located at 1005 Pleasant Run Rd., Lancaster, Texas 75146; where at least three (3) employees were exposed to head injuries from impact, of falling or flying objects without the use of any hard hats.
Recent events (1)
- — Z (S) $1600
1926.451 H01
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(h)(1): In addition to wearing hardhats each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toeboards, screens, or guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects. When the falling objects are too large, heavy or massive to be contained or deflected by any of the above-listed measures, the employer shall place such potential falling objects away from the edge of the surface from which they could fall and shall secure those materials as necessary to prevent their falling. This violation occurred on October 18, 2012, at a workplace located at 1005 Pleasant Run Rd., Lancaster, Texas 75146; where at least three (3) employees were observed working from a three tiered scaffold without the use of toe boards.
Recent events (1)
- — Z (S) $0
1926.451 B01
- Issued
- Abate by
- Penalty
- Initial $2800.00 · Current $2800.00
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as follows: This violation occurred on October 18, 2012, at a workplace located at 1005 Pleasant Run Rd., Lancaster, Texas 75146; where at least three (3) employees were observed working from a three tiered scaffolding that was not fully planked.
Recent events (1)
- — Z (S) $2800
1926.451 G04 I
- Issued
- Abate by
- Penalty
- Initial $0.00 · Current $0.00
General-duty citation text
29 CFR 1926.451(g)(4)(i):Guardrail systems were not installed along all open sides and ends of platforms. Guardrail systems were not installed before the scaffold was released for use by employees other than erection/dismantling crews. This violation occurred on October 18, 2012, at a workplace located at 1005 Pleasant Run Rd., Lancaster, Texas 75146; where at least three (3) employees were observed working from a three tiered scaffold without the use of guard rail systems.
Recent events (1)
- — Z (S) $0
1926.451 E01
- Issued
- Penalty
- Initial $1600.00 · Current $1600.00
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were being used as a means of access. This violation occurred on October 18, 2012, at a workplace located at 1005 Pleasant Run Rd., Lancaster, Texas 75146; where at least three (3) employees were observed accessing scaffold using the end frame as a means of access.
Recent events (1)
- — Z (S) $1600
More inspections in this industry (NAICS 238140)
RENO, NV—2026-07-16
DC MASONRY
WINNETKA, IL—2026-07-15
CHICAGO STUCCO CO.
LODI, NJ—2026-07-15
J & O MASONRY CONTRACTORS
DORAVILLE, GA—2026-07-14
SUDLOW CONCRETE, INC.
FLAGLER BEACH, FL—2026-07-14
PLANET DESIGN SERVICES, INC.
More inspections in TX
WICHITA FALLS, TX—2026-07-16
UNITED RENTALS, INC.
SAN MARCOS, TX—2026-07-16
CASA MECHANICAL SERVICES, LTD.
CLARKSVILLE, TX—2026-07-15
SEQUOIAS TREE EXPERT LLC
EL PASO, TX—2026-07-15
SURE STEEL
CORPUS CHRISTI, TX—2026-07-15
NORTH STAR ENERGY SOLUTIONS LLC
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336927587.