NEWARK, NJ —
OSHA Inspection: E&L BATTERY & IGNITION COMPANY
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of E&L BATTERY & IGNITION COMPANY in 28 WILLIAM STREET, NEWARK, NJ 07102 (NAICS 493110). OSHA activity number 336963582.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- E&L BATTERY & IGNITION COMPANY
- Site address
- 28 WILLIAM STREET
- City
- NEWARK
- State
- NJ
- ZIP
- 07102
- Mailing
- 28 WILLIAM STREET, NEWARK, NJ 07102
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 493110
- Employees
- 65
- Ownership type
- A
Citations
4 citations on file for this inspection.
1910.1001 J02 I
- Issued
- Jan 30, 2013
- Abate by
- Mar 19, 2013
- Penalty
- Initial $3,500 · Current $3,500
9020
General-duty citation text
29 CFR 1910.1001(j)(2)(i): The building owner, facility owner or employer did not determine the presence, location, and quantity of ACM or PACM at the worksite and did not exercise due diligence in complying with these requirements to inform employers and employees about the presence and location of asbestos-containing material (ACM) and presumed asbestos containing material (PACM). a) Basement storage area, E&L Battery and Ignition Company site located on 28 William Street, Newark, NJ 07102. The employer did not perform a survey or inform the employees of the presence and location of ACM and/or PACM. The picker and custodial employees are required in their duties to enter this area which contains damaged thermal sytems insulation with 42% chrysotile asbestos. Condition noted on or about 10/19/2012.
Recent events (1)
- — Z (S) $3500
1910.1001 J04 I
- Issued
- Jan 30, 2013
- Abate by
- Mar 19, 2013
- Penalty
- Initial $3,500 · Current $3,500
9020
General-duty citation text
29 CFR 1910.1001(j)(4)(i): Warning labels were not affixed to all raw materials, mixtures, scrap, waste, debris, and other products containing asbestos fibers, or to their containers: a) Basement storage area, E&L Battery and Ignition Company site located on 28 William Street, Newark, NJ 07102. The employer did not affix asbestos warning labels where ACM was present to including thermal systems insulation on piping. The bulk sample taken on the thermal systems insulation was found to contain 42% chrysotile asbestos. Condition noted on or about 10/19/2012.
Recent events (1)
- — Z (S) $3500
1910.1001 J07 IV
- Issued
- Jan 30, 2013
- Abate by
- Mar 19, 2013
- Penalty
- Initial $3,500 · Current $3,500
9020
General-duty citation text
29 CFR 1910.1001(j)(7)(iv): The employer did not provide, at no cost to employees who perform housekeeping operations in an area which contains presumed asbestos-containing material (PACM) and/or other asbestos-containing material (ACM), an asbestos awareness training course: a) Basement storage area, E&L Battery and Ignition Company site located on 28 William Street, Newark, NJ 07102. Employees who performed housekeeping activities in the basement storage area where asbestos containing thermal insulation was located were not provided asbestos hazard awareness training. A bulk sample of the damaged thermal systems insulation was found to have 42% chrysotile asbestos. Condition noted on or about 10/19/2012.
Recent events (1)
- — Z (S) $3500
1910.1001 K01
- Issued
- Jan 30, 2013
- Abate by
- Mar 19, 2013
- Penalty
- Initial $3,500 · Current $3,500
9020
General-duty citation text
29 CFR 1910.1001(k)(1): All surfaces were not maintained as free as practicable of ACM waste and debris and accompanying dust: a) Basement storage area, E&L Battery and Ignition Company site located on 28 William Street, Newark, NJ 07102. The presumed asbestos containing thermal systems insulation was friable and in poor condition. A bulk sample taken from the basement thermal systems insulation was found to contain 42% chrysotile asbestos. Condition noted on or about 10/19/2012.
Recent events (1)
- — Z (S) $3500
More inspections at E&L Battery & Ignition Company
View E&L Battery & Ignition Company's full OSHA safety record →
More inspections in this industry (NAICS 493110)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336963582.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.