OSHA Inspection: ALIGN ROOFING, LLC

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ALIGN ROOFING, LLC in 250 CHERRY RIDGE DRIVE, JACKSONVILLE, FL 32222 (NAICS 238160). OSHA activity number 336975784.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Align Roofing, LLC — free Get an email when a new federal OSHA severe-injury report for Align Roofing, LLC is published. One employer, no account, unsubscribe in one click.
Establishment
ALIGN ROOFING, LLC
Site address
250 CHERRY RIDGE DRIVE
City
JACKSONVILLE
State
FL
ZIP
32222
Mailing
1219 ROMNEY STREET, JACKSONVILLE, FL 32211
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238160
Employees
7
Ownership type
A

5 citations on file for this inspection.

1926.102 A01

Other-than-serious 1 instance 1 exposed
Issued
Nov 8, 2012
Penalty
Initial $1,600 · Current $600 Reduced
29 CFR 1926.102(a)(1):  Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents.    a.  On or about October 18, 2012, on the 6:12 pitch roof, an employee using a pneumatic nailer to install shingles was not wearing safety glasses, exposing himself to eye injuries.
Recent events (2)
  • — I (O) $600
  • — Z (S) $1600

1926.1053 B16

Serious Gravity 5 1 instance 7 exposed
Issued
Nov 8, 2012
Penalty
Initial $2,000 · Current $1,500 Reduced
29 CFR 1926.1053(b)(16):  Portable ladder(s) with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components, were not either immediately:    a.  On or about October 18, 2012, the 28-foot extension ladder used to access the roof had a bent footing, exposing employees to a 15 feet fall hazard.
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2000

1926.1053 B21

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(21):  Employees were not grasping the ladder with at least one hand when progressing up and/or down the ladder:    a.  On or about October 19, 2012, employees were climbing a 28-foot extension ladder while carrying material and equipment in their hands.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.1053 B22

Serious Gravity 5 1 instance 3 exposed
Issued
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.1053(b)(22):  Employees  using ladders were carrying objects or loads that could cause the employee to lose balance and fall:    a.  On or about October 18, 2012, employees were climbing a 28-foot extension ladder while carrying material and equipment that could cause them to lose their balance and fall.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.501 B13

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2012
Penalty
Initial $4,000 · Current $2,000 Reduced
Align Roofing, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard (29 CFR 1926.501(b)(13) which was contained in OSHA inspection number 315482133, citation 01, item number 001, issued on December 12, 2011, with respect to a workplace at 923-1st Avenue South, Jacksonville Beach, Florida 32250. The final order date was January 28, 2012.    29 CFR 1926.501(b)(13):  Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501(b):     a.  On or about October 18, 2012, on the 6:12 pitch roof, employees installing shingles were not protected from a 24 feet fall hazard by the use of a fall protection system.
Recent events (2)
  • — I (S) $2000
  • — Z (R) $4000

View Align Roofing, LLC's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336975784.