WEST CREEK, NJ —
OSHA Inspection: A. H. E. MANUFACTURING, INC.
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of A. H. E. MANUFACTURING, INC. in 107 CEMETARY ROAD, WEST CREEK, NJ 08092 (NAICS 333921). OSHA activity number 336982798.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A. H. E. MANUFACTURING, INC.
- Site address
- 107 CEMETARY ROAD
- City
- WEST CREEK
- State
- NJ
- ZIP
- 08092
- Mailing
- 127 ROUTE 9 SOUTH, BARNEGAT, NJ 08005
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333921
- Employees
- 4
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.133 A01
- Issued
- Mar 26, 2013
- Abate by
- Apr 19, 2013
- Penalty
- Initial $1,020 · Current $765 Reduced
General-duty citation text
29 CFR 1910.133(a)(1): Protective eye equipment was not required where there was a reasonable probability of injury that could be prevented by such equipment: a) Spray Room - Appropriate eye protection such as, but not limited to safety glasses with side shields was not worn by employees who used compressed air to clean elevator components after sanding. On or about 2/7/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $765
- — Z (S) $1020
1910.242 B
- Issued
- Mar 26, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Spray Room - The compressed air used for cleaning elevator components after sanding was measured at approximately 90 psi. On or about 2/7/13.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.134 E01
- Issued
- Mar 26, 2013
- Abate by
- Apr 19, 2013
- Penalty
- Initial $1,020 · Current $765 Reduced
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Spray room - Medical evaluations were not provided for employees who wore tight fitting respirators such as, but not limited to 3M 5300 negative pressure half mask air purifying respirators and Moldex full face negative pressure half mask air purifying respirators. On or about 2/7/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (S) $765
- — Z (S) $1020
1910.134 C01
- Issued
- Mar 26, 2013
- Abate by
- Apr 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Spray room - A written respirator program was not developed. Employees wore tight fitting respirators such as, but not limited to 3M 5300 negative pressure half mask air purifying respirators and Moldex full face negative pressure half mask air purifying respirators. On or about 2/7/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.134 H02 I
- Issued
- Mar 26, 2013
- Abate by
- Apr 19, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.134(h)(2)(i): Respirators were not stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals or were not packed or stored to prevent deformation of the facepiece and exhalation valve: a) Establishment - Respirators including, but not limited to 3M 5300 negative pressure half mask air purifying respirators and Moldex full face negative pressure half mask air purifying respirators were stored by hanging them on nails. They were not stored in sealable containers. On or about 2/7/13. NOTE: THE EMPLOYER IS REQUIRED TO SUBMIT ABATEMENT CERTIFICATION FOR THIS ITEM. FAILURE TO COMPLY WILL RESULT IN AN ADDITIONAL PENALTY OF $1000.00 IN ACCORDANCE WITH 29 CFR 1903.19.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections in this industry (NAICS 333921)
More inspections in NJ
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336982798.