WATFORD CITY, ND —
OSHA Inspection: PYRAMID RESIDENTIAL CONSTRUCTION, INC.
Federal Agency inspection · Safety discipline
At a glance
On , OSHA opened a federal Agency safety inspection of PYRAMID RESIDENTIAL CONSTRUCTION, INC. in 600 SECOND AVENUE SW, WATFORD CITY, ND 58854 (NAICS 238170). OSHA activity number 336986187.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- PYRAMID RESIDENTIAL CONSTRUCTION, INC.
- Site address
- 600 SECOND AVENUE SW
- City
- WATFORD CITY
- State
- ND
- ZIP
- 58854
- Mailing
- 11587 ALDER STREET NW, COON RAPIDS, MN 55448
What kind of inspection was it?
- Inspection type
- Federal Agency (M)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 F07
- Issued
- Feb 7, 2013
- Abate by
- Feb 25, 2013
- Penalty
- Initial $2,800 · Current $2,520 Reduced
General-duty citation text
29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration: (a) On or about October 11, 2012, and at times prior to that date, for the employees and management officials involved in the erection of the Alum-a-Pole Pump Jack Scaffold System without adequate fall protection systems or adequate bracing in place, located at 600 Second Avenue SW in Watford City, North Dakota.
Recent events (2)
- — I (S) $2520
- — Z (S) $2800
1926.454 A
- Issued
- Feb 7, 2013
- Abate by
- Feb 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: (a) On or about October 11, 2012, and at times prior to that date, for the employees installing siding from an Alum-a-Pole Pump Jack Scaffold System without adequate fall protection systems or adequate bracing in place, located at 600 Second Avenue SW in Watford City, North Dakota.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.451 G01
- Issued
- Feb 7, 2013
- Abate by
- Feb 11, 2013
- Penalty
- Initial $2,800 · Current $2,520 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet above a lower level was not protected from falling to that lower level: (a) On or about October 11, 2012, and at times prior to that date, for the employees installing siding from an Alum-a-Pole Pump Jack Scaffold System with an inadequate mid rail installed and exposed to fall hazards of approximately 26 feet, located at 600 Second Avenue SW in Watford City, North Dakota.
Recent events (2)
- — I (S) $2520
- — Z (S) $2800
1926.501 B01
- Issued
- Feb 7, 2013
- Abate by
- Feb 11, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: (a) On or about October 11, 2012, and at times prior to that date, for the employees installing bracing for an Alum-a-Pole Pump Jack Scaffold System on the roof of a four-story hotel and exposed to fall hazards of approximately 44 feet, located at 600 Second Avenue SW in Watford City, North Dakota.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.452 J02
- Issued
- Feb 7, 2013
- Abate by
- Feb 11, 2013
- Penalty
- Initial $2,800 · Current $2,520 Reduced
General-duty citation text
29 CFR 1926.452(j)(2): Poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary: (a) On or about October 11, 2012, and at times prior to that date, for the employees and management officials involved in the erection of the Alum-a-Pole Pump Jack Scaffold System with one brace installed at approximately 44 feet and no intermediate bracing, located at 600 Second Avenue SW in Watford City, North Dakota.
Recent events (2)
- — I (S) $2520
- — Z (S) $2800
More inspections in this industry (NAICS 238170)
More inspections in ND
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 336986187.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.