Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ST. LOUIS MARBLE CO.

Complaint inspection · Health discipline

On , OSHA opened a complaint health inspection of ST. LOUIS MARBLE CO. in 1565 FENPARK, FENTON, MO 63026 (NAICS 337125). OSHA activity number 336989389.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ST. Louis Marble CO. — free Get an email when a new federal OSHA severe-injury report for ST. Louis Marble CO. is published. One employer, no account, unsubscribe in one click.
Site address
1565 FENPARK
City
FENTON
State
MO
ZIP
63026
Mailing
1565 FENPARK, FENTON, MO 63026
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Case closed
Last modified
Data loaded
NAICS code
337125
Employees
9
Ownership type
A

10 citations on file for this inspection.

1910.22 A01

Serious Gravity 5 1 instance 7 exposed
Issued
Mar 28, 2013
Abate by
May 9, 2013
Penalty
Initial $2,000 · Current $500 Reduced
29 CFR 1910.22(a)(1):     All places of employment, passageways, storerooms or service rooms were not kept clean and orderly or in a sanitary condition.    Floors, elecrical panel boxes, electrical fittings,conduits, storage racks, overhead rafters, structural beams, walls, employee break rooms and restrooms were not kept free from settled dust.
Recent events (2)
  • — I (S) $500
  • — Z (S) $2000

1910.95 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Mar 28, 2013
Abate by
May 31, 2013
Penalty
Initial $1,600 · Current $400 Reduced
29 CFR 1910.95(c)(1):     The employer did not administer a continuing, effective hearing conservation program as described in 29 CFR 1910.9(c) through (o) whenever employee noise exposures equal or exceed an 8-hour time-weighted average sound level of 85 decibels measured on the A scale, or equivalently a dose of fifty percent:    In the finishing area, employees conducting grinding and buffing operations using powerd tools, were exposed to noise level above 85 dBA on 8 hr. Time Weighted Average (TWA), the employer did not establish an effective hearing protection program.
Recent events (2)
  • — I (S) $400
  • — Z (S) $1600

1910.132 A

Serious Gravity 5 3 instances 5 exposed
Issued
Mar 28, 2013
Abate by
Apr 18, 2013
Penalty
Initial $1,600 · Current $400 Reduced
29 CFR 1910.132(a):     Protective equipment was not used when necessary whenever hazards capable of causing injury and impairment were encountered:    Employees working with chemicals that can irritate the skin, were not required to wear protective gloves.    (1) Near the spraying booth the employee was wiping down (cleaning) fixtures mold with a solution containing Thrimethylbenzene without wearing protective gloves(2) Employee conducting spraying operation was not using gloves to protect him from skin injuries.    (3) Employee working in the mixing area was not using gloves to protect him from skin injuries.
Recent events (2)
  • — I (S) $400
  • — Z (S) $1600

1910.151 C

Serious Gravity 1 1 instance 7 exposed
Issued
Mar 28, 2013
Abate by
May 9, 2013
Penalty
Initial $1,200 · Current $300 Reduced
29 CFR 1910.151(c):     Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    At the plant, where chemicals such as styrene and Trimethylbenzene were used on regular basis, eye wash apparatus to allow the employees reinse their eyes was not made availeble.
Recent events (2)
  • — I (S) $300
  • — Z (S) $1200

1910.305 B01 I

Serious Gravity 5 1 instance 3 exposed
Issued
Mar 28, 2013
Abate by
Apr 18, 2013
Penalty
Initial $1,600 · Current $400 Reduced
29 CFR 1910.305(b)(1)(i):     Openings through which conductors entered cutout boxes, cabinets, or fittings were not effectively closed.    Near the mixing area, an electrical box located on the west wall had fittings that were not effectivelly closed.
Recent events (2)
  • — I (S) $400
  • — Z (S) $1600

1910.305 B01 II

Serious Gravity 5 3 instances 5 exposed
Issued
Mar 28, 2013
Abate by
Apr 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(1)(ii):     Unused openings in boxes, cabinets, or fittings were not effectively closed.    In the finishing area, an electrical panelbox located on the east wall with 3(three) missing breakers, the unused openinimngs were not closed.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.22 D

Other-than-serious 1 instance 2 exposed
Issued
Mar 28, 2013
Abate by
Apr 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.22(d):     In every building or structure, the loads approved by the building official were not marked on plates of approved design and were not securely affixed:      Above the grinding booth stucture, molds of unknown weight were stored while the weight limit for such structure was not marked on plates. This condition pose a crash hazard on those employees working beneath the structure.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.134

Other-than-serious 1 instance 5 exposed
Issued
Mar 28, 2013
Abate by
Apr 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.134 App D:     The employer shall provide the basic advisory information on respirators, as presented in Appendix D of this section, in any written or oral format, to employees who wear respirators when such use is not required by this section or by the employer:    In the mixing area employee using a N95 respirators was not provided with information contained in appendix D of this standard.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C01

Other-than-serious 3 instances 15 exposed
Issued
Mar 28, 2013
Abate by
Apr 18, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1):     Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries    1. Near the water cooler in the finishing area a portable fire extinguisher was not mounted.     2. In the finishing area, a portable fire extinguisher was left on the floor.    3. Nearthe staff rest room, a portable fire extinguisher was not mounted.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.178 L06

Other-than-serious 1 instance 2 exposed
Issued
Mar 28, 2013
Abate by
May 9, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(6):     The employer did not certify that each operator has been trained and evaluated as required by this paragraph (l):    On the production floor,  where fork trucks are used on daily basis, the employer did not certify that each operator was trained.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0