PORTLAND, PA —
OSHA Inspection: ULTRA-POLY CORPORATION
Complaint inspection · Health discipline
At a glance
On , OSHA opened a complaint health inspection of ULTRA-POLY CORPORATION in 102 DEMI ROAD, PORTLAND, PA 18351 (NAICS 325211). OSHA activity number 336994587.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- ULTRA-POLY CORPORATION
- Site address
- 102 DEMI ROAD
- City
- PORTLAND
- State
- PA
- ZIP
- 18351
- Mailing
- 102 DEMI ROAD, PORTLAND, PA 18351
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325211
- Employees
- 110
- Ownership type
- A
Citations
3 citations on file for this inspection.
1910.134 E01
- Issued
- Mar 21, 2013
- Abate by
- Apr 25, 2013
- Penalty
- Initial $2,066 · Current $1,550 Reduced
9032
General-duty citation text
29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employees ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a.) Rubber Roadway/talc Operation - On or about February 20. 2013, Employees who were required to wear half face negative pressure respirators (dust masks) while operating the talc operation, did not receive a medical evaluation as required.
Recent events (2)
- — I (S) $1549.5
- — Z (S) $2066
1910.134 F01
- Issued
- Mar 21, 2013
- Abate by
- Apr 25, 2013
- Penalty
- Initial $0 · Current $0
9032
General-duty citation text
29 CFR 1910.134(f)(1): The employer did not ensure that employee(s) required to use a tight-fitting face piece respirator passed the appropriate qualitative fit test (QLFT) or quantitative fit test (QNFT); a.) Rubber Roadway/talc Operation - On or about February 20. 2013, Employees who were required to wear half face negative pressure respirators (dust masks) while operating the talc operation were not properly fitted prior to wearing the respirator in the workplace.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.242 B
- Issued
- Mar 21, 2013
- Penalty
- Initial $1,756 · Current $1,317 Reduced
9032
General-duty citation text
29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i: a.) Rubber Roadway/talc Operation - On or about February 20, 2013, Employees, operators, used air for cleaning that was not reduced below the required pressure exposing themselves to abrasions and contusions.
Recent events (2)
- — I (S) $1317
- — Z (S) $1756
More inspections at Ultra-Poly Corporation