OSHA Inspection: BIO GENE COMPANY

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BIO GENE COMPANY in 5491 TRI-COUNTY HIGHWAY, SARDINIA, OH 45171 (NAICS 424510). OSHA activity number 337005789.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch BIO Gene Company — free Get an email when a new federal OSHA severe-injury report for BIO Gene Company is published. One employer, no account, unsubscribe in one click.
Establishment
BIO GENE COMPANY
Site address
5491 TRI-COUNTY HIGHWAY
City
SARDINIA
State
OH
ZIP
45171
Mailing
5491 TRI-COUNTY HIGHWAY, SARDINIA, OH 45171
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424510
Employees
8
Ownership type
A

7 citations on file for this inspection.

1910.23 C01

Other-than-serious 1 instance 3 exposed
Issued
Nov 30, 2012
Penalty
Initial $2,000 · Current $500 Reduced
29 CFR 1910.23(c)(1):     Every open-sided floor or platform 4 feet or more above adjacent floor or ground level shall be guarded by a standard railing (or the equivalent as specified in paragraph (e)(3) of this section) on all open sides except where there is entrance to a ramp, stairway, or fixed ladder. The railing shall be provided with a toeboard wherever, beneath the open sides,    At the Loading Dock Area, employees walking on the sidewalk parallel to the loading dock to the Warehouse were exposed to a four foot fall hazard due to the lack of any fall protection.
Recent events (2)
  • — I (O) $500
  • — Z (S) $2000

1910.132 A

Serious Gravity 5 1 instance 1 exposed
Issued
Nov 30, 2012
Abate by
Jan 18, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.132(a):     Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.    On or about August 12, 2012 in the Bagger Room, an employee was exposed to a 12 foot fall hazard due to the lack fall protection on the platform while assisting the owner in replacing four screens on the Clipper Seed Cleaner Machine.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 30, 2012
Abate by
Jan 18, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1910.147(c)(1):     Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.      The Company had not established nor imiplemented an energy control program consisting of energy control procedures, training and periodic inspections.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1910.303 B02

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 30, 2012
Abate by
Dec 19, 2012
Penalty
Initial $1,200 · Current $1,200
29 CFR 1910.303(b)(2):     Installation and use. Listed or labeled equipment shall be installed and used in accordance with any instructions included in the listing or labeling.    In the Warehouse Bagger Room, a 110 Volt AC six outlet surge suppressor was being used in a dusty environment from the operation of the Clipper Seed Cleaner Machine and tote filler, in violation of its UL Listing and Labeling.
Recent events (2)
  • — I (S) $1200
  • — Z (S) $1200

1910.305 B02 I

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 30, 2012
Abate by
Dec 7, 2012
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1910.305(b)(2)(i):     All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.    In the Building B portion of the Warehouse, the faceplate on a 110 Volt AC two receptacle outlet was missing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1910.305 G01 IV A

Serious Gravity 1 1 instance 1 exposed
Issued
Nov 30, 2012
Penalty
Initial $1,200 · Current $0 Reduced
29 CFR 1910.305(g)(1)(iv)(A):     As a substitute for the fixed wiring of a structure;    In the Bagger Room, an extension cord set was used in lieu of fixed wiring to power the fixed meter located on the steel beam for the floor scale.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1200

1910.37 B02

Other-than-serious 1 instance 3 exposed
Issued
Nov 30, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(2):     Each exit must be clearly visible and marked by a sign reading "Exit."    In the Warehouse building, two doors leading to the outside of the building, one in the Bagger Room and one in Building B were not marked with a sign reading "Exit".
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View BIO Gene Company's full OSHA safety record →