HEREFORD, TX —
OSHA Inspection: MAGNUM MINERALS LLC
Complaint inspection · Safety discipline
At a glance
On , OSHA opened a complaint safety inspection of MAGNUM MINERALS LLC in 200 FRONT STREET, HEREFORD, TX 79045 (NAICS 325998). OSHA activity number 337014781.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MAGNUM MINERALS LLC
- Site address
- 200 FRONT STREET
- City
- HEREFORD
- State
- TX
- ZIP
- 79045
- Mailing
- 3510 US HWY 385, HEREFORD, TX 79045
What kind of inspection was it?
- Inspection type
- Complaint (B)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 325998
- Employees
- 3
- Ownership type
- A
Citations
5 citations on file for this inspection.
1910.22 A03
- Issued
- Mar 27, 2013
- Abate by
- Apr 26, 2013
- Penalty
- Initial $2,100 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.22(a)(3): To facilitate cleaning, every floor, working place, and passageway was not kept free from protruding nails, splinters, holes, or loose boards. On or about October 23, 2012, employees were exposed to trip and fall hazards in that the employer did not ensure that walking working surface was free of unused holes in the upper level platform.
Recent events (2)
- — I (O) $1000
- — Z (S) $2100
1910.253 B02 II
- Issued
- Mar 27, 2013
- Abate by
- Apr 26, 2013
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1910.253(b)(2)(ii): Inside of buildings, cylinders were not stored in a well-protected, well-ventilated, dry location, at least 20 (6.1 m) feet from highly combustible materials such as oil or excelsior. Cylinders were not stored in definitely assigned places away from elevators, stairs, or gangways. Assigned storage spaces were not located where cylinders will not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons. Cylinders were not kept in unventilated enclosures such as lockers and cupboards. On or about October 23, 2012, employees were exposed to fire/explosion hazards in that the employer did not ensure that oxygen and acetylene cylinders were secured.
Recent events (2)
- — I (S) $2800
- — Z (S) $2800
1910.253 B04 I
- Issued
- Mar 27, 2013
- Abate by
- Apr 26, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(i): Oxygen cylinders was stored near highly combustible material, especially oil and grease; or near reserve stocks of carbide and acetylene or other fuel-gas cylinders, or near any other substance likely to cause or accelerate fire; or in an acetylene generator compartment. On or about October 23, 2012, employees were exposed to fire/explosion hazards in that the employer did not ensure that the oxygen cylinder was not stored near the acetylene cylinder.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.253 B04 III
- Issued
- Mar 27, 2013
- Abate by
- Apr 26, 2013
- Penalty
- Initial $2,800 · Current $0 Reduced
General-duty citation text
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour. On or about October 23, 2012, employees were exposed to fire/explosion hazards in that the employer did not ensure that an oxygen cylinder was not stored at least 20 feet from an acetylene cylinder.
Recent events (2)
- — I (S) $0
- — Z (S) $2800
1910.253 B02 IV
- Issued
- Mar 27, 2013
- Abate by
- Apr 26, 2013
- Penalty
- Initial $2,800 · Current $1,700 Reduced
General-duty citation text
29 CFR 1910.253(b)(2)(iv): Valve protection caps, where cylinder was designed to accept a cap, was not always in place, hand-tight, except when cylinders were in use or connected for use. On or about October 23, 2012, employees were exposed to fire/explosion hazards in that the employer did not ensure that the value protection cap was in place on the acetylene cylinder.
Recent events (2)
- — I (S) $1700
- — Z (S) $2800
More inspections at Magnum Minerals LLC
View Magnum Minerals LLC's full OSHA safety record →
More inspections in this industry (NAICS 325998)
More inspections in TX
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337014781.