DE SOTO, MO —
OSHA Inspection: FRC INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of FRC INC. in 4280 FOUNTAIN CITY ROAD, DE SOTO, MO 63020 (NAICS 423930). OSHA activity number 337014823.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- FRC INC.
- Site address
- 4280 FOUNTAIN CITY ROAD
- City
- DE SOTO
- State
- MO
- ZIP
- 63020
- Mailing
- 4280 FOUNTAIN CITY ROAD, DE SOTO, MO 63020
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 423930
- Employees
- 3
- Ownership type
- A
Citations
11 citations on file for this inspection.
5(a)(1)
- Issued
- Oct 31, 2012
- Abate by
- Dec 14, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a machine guarding hazard: Inside of the Can Crushing Department, employees operating the following vertical balers were not instructed in the safe work methods as described by the manufacturer: a/ Selco Baler, m/n VS-10, s/n 099765738. b/ Selco Baler, unknown m/n or s/n. Training records identifying the names of the employees and date of instruction were not maintained. One method of abatement to correct the apparent hazard is to perform monthly inspections as required by ANSI 245.5-2004, paragraph 7.1.b. DISCLAIMER: a/ The employer is not limited to the abatement method(s) suggested by OSHA. b/ The employer is resonsible for selecting and implementing an effective abatement method.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
5(a)(1)
- Issued
- Oct 31, 2012
- Abate by
- Dec 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to a machine guarding hazard: Inside of the Can Crushing Department, the following vertical balers were not inspected for defects on a periodic and regular basis: a/ Selco Baler, m/n VS-10, s/n 099765738. b/ Selco Baler, unknown m/n or s/n. Records of such inspections were not maintained. One method of abatement to correct the apparent hazard is to perform monthly inspections as required by ANSI 245.5-2004, paragraph 7.1.g. DISCLAIMER: a/ The employer is not limited to the abatement method(s) suggested by OSHA. b/ The employer is resonsible for selecting and implementing an effective abatement method.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.212 A03 II
- Issued
- Oct 31, 2012
- Abate by
- Nov 7, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.212(a)(3)(ii): Point(s) of operation of machinery were not guarded to prevent employee(s) from having any part of their body in the danger zone(s) during operating cycle(s): Inside of the Can Crushing Department, the point-of-operation belonging to the following machines was inadequately guarded: a/ Selco Baler, m/n VS-10, s/n 099765738. b/ Selco Baler, unknown m/n or s/n.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C01
- Issued
- Oct 31, 2012
- Abate by
- Dec 14, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: A written lockout/tagout program was not established for employees who service the following machines: a/ Alligator shear, unknown make, m/n or s/n. b/ Can crushing machine, unknown make, m/n or s/n. c/ Selco Vertical Baler, m/n VS-10, s/n 099765738. d/ Selco Vertical Baler, unknown m/n or s/n. e/ Nelmor Granulator, s/n 122697. f/ Bloapco Shredder/Blower, unknown m/n or s/n. g/ Toyota Fork Truck, m/n 7F6025, s/n 77462. h/ Caterpillar Skid Loader, unknown m/n or s/n.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.147 C04 I
- Issued
- Oct 31, 2012
- Abate by
- Dec 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: Specific procedures were not developed in writing for the following machinery: a/ Alligator shear, unknown make, m/n or s/n, 230 volts and motor oil pressure of an unknown quantity. b/ Bloapco Shredder/Blower, unknown m/n or s/n, 460 volts and 1700 p.s.i. hydraulics. c/ Toyota Fork Truck, m/n 7F6025, s/n 77462, electrical battery, blocking, and elevated forks. d/ Caterpillar Skid Loader, unknown m/n or s/n, electrical battery, blocking, and elevated forks.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.147 C05 I
- Issued
- Oct 31, 2012
- Abate by
- Dec 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: Energy isolation devices were not applied to the following machines prior to servicing: a/ Alligator shear, unknown make, m/n or s/n, 230 volts and motor oil pressure of an unknown quantity. b/ Bloapco Shredder/Blower, unknown m/n or s/n, 460 volts and 1700 p.s.i. hydraulics. c/ Nelcor Granulator, s/n 122697.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.178 L02 II
- Issued
- Oct 31, 2012
- Abate by
- Dec 14, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.178(l)(2)(ii): Training did not consist of a combination of formal instruction (e.g., lecture, discussion, interactive computer learning, video tape, written material), practical training (demonstrations performed by the trainer and practical exercises performed by the trainee), and evaluation of the operators performance in the workplace: a/ Operators of the Toyota Fork Truck, m/n 7F6025, s/n 77462, were not provided with formal instruction to safely operate this piece of equipment.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.178 L06
- Issued
- Oct 31, 2012
- Abate by
- Dec 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.178(l)(6): The employer did not certify that each operator had been trained and evaluated as required by this paragraph (l): a/ Operators of the Toyota Fork Truck, m/n 7F6025, s/n 77462, were not certified.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1910.334 A02 II
- Issued
- Oct 31, 2012
- Abate by
- Nov 7, 2012
- Penalty
- Initial $2,000 · Current $1,000 Reduced
General-duty citation text
29 CFR 1910.334(a)(2)(ii): There was a defect or evidence of damage that could have exposes an employee to injury and the defective or damaged item was not removed from service: a/ Inside of the electrical supply room, the outer insulation belonging to a orange flexible cord was damaged adjacent to the green plug. This flexible cord was used to provide electrical power to a Marathon Electric Motor, Cat No. 6151.
Recent events (2)
- — I (S) $1000
- — Z (S) $2000
1910.132 D02
- Issued
- Oct 31, 2012
- Abate by
- Dec 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.132(d)(2): The employer did not verify, through a written certification, that the required workplace hazard assessment had been performed: a/ A certification that the workplace hazard assessment was not accomplished.
Recent events (2)
- — I (O) $0
- — Z (O) $0
1910.1200 E01
- Issued
- Oct 31, 2012
- Abate by
- Dec 14, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: a/ A written hazard communication program was not developed or implemented that addressed how labeling, material safety data sheets, and employee training.
Recent events (2)
- — I (O) $0
- — Z (O) $0
More inspections at FRC INC.