Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ALL SPUN METAL PRODUCTS, L.L.C.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ALL SPUN METAL PRODUCTS, L.L.C. in 1877 BUSSE HIGHWAY, DES PLAINES, IL 60016 (NAICS 332710). OSHA activity number 337031983.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch ALL Spun Metal Products, L.L.C. — free Get an email when a new federal OSHA severe-injury report for ALL Spun Metal Products, L.L.C. is published. One employer, no account, unsubscribe in one click.
Site address
1877 BUSSE HIGHWAY
City
DES PLAINES
State
IL
ZIP
60016
Mailing
1877 BUSSE HIGHWAY, DES PLAINES, IL 60016
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332710
Employees
4
Ownership type
A

16 citations on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to an amputation hazard from the mechanical press die conitinuing to cycle:    a) Press Department - Provision was not made to prevent the Whitney and Jensen mechanical power press model #130, serial #A1211161, from automatically restarting upon restoration of power after a power source failure.      Among other methods, one feasible and acceptable means of abatment in an event of interruption in the electrical supply to the press would be to provide an electrical device that is designed to prevent the press from restarting automatically when power is restored, such as a magnetic restart or similiar device, as prescribed by the American National Standard Institute for Mechanical Power Presses, ANSI B11.1 - 2009, Section 6.1.5.
Recent events (1)
  • — Z (S) $0

1910.147 C01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of a control procedure, employee training, and periodic inspections to ensure that be employee performed any servicing or maintenance on a machine or equipment where unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment would be isolated, and rendered inoperative in accordance with CFR 1910.147(c)(4):    a) The employer did not establish, utilize an energy control procedure (lockout/tag-out program), and provide training on the energy control procedure to ensure that all required elements of the procedure were understood by employees, and that the knowledge and skills required for the safe application, usage and removal of the energy controls were acquired by employees performing servicing or maintenance on the full revolution mechanical power press, spinning machines, and punch presses.
Recent events (1)
  • — Z (S) $0

1910.178 L01 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).     a) Throughout Plant Areas - The employer did not train and evaluate each operator who is authorized to operate the Kamatsu Power Industrial Truck serial #4664, to ensure they were competent to operate the truck safely.
Recent events (1)
  • — Z (S) $0

1910.213 L02

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.213(l)(2): Boring bits were not provided with a guard that enclosed all portions of the bit and chuck above the material being worked:     a) Press Room - The employer had three Commander Johansson Milling Machines serial #33162B, that did not have guards to protect employees from the rotating spindles and flying chips.
Recent events (1)
  • — Z (S) $0

1910.217 B03 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.217(b)(3)(i): Mechanical power press(es) using full revolution clutches did not incorporate a singlestroke mechanism:    a) Press Department - The Rouselle full revolution mechanical power press model #4G, serial #129, did not have a singlestroke mechanism.
Recent events (1)
  • — Z (S) $0

1910.217 B04 I

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.217(b)(4)(i): Pedal mechanism(s) on mechanical power press(es) full revolution clutches were not protected to prevent unintended operation from falling or moving objects or by accidental stepping onto the pedals:    a) The Whitney-Jensen model #130, serial #A1211161, full revolution mechanical power press machine did not have the foot pedal protected against unintended or accidental stepping onto the pedal.
Recent events (1)
  • — Z (S) $0

1910.217 C01 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.217(c)(1)(i): The employer did not provide and ensure the usage of "point of operation guards" or properly applied point of operation devices on every operation performed on mechanical power press(es):      a) Punch Press Department - The point of operation on the Rouselle model #4G , serial #129, full revolution mechanical power press was not guarded.         b) Punch Press Department - The point of operation on the Whitney and Jensen model #130, serial #A121161, full revolution mechanical power press was not guarded.
Recent events (1)
  • — Z (S) $0

1910.217 D09 I

Serious Gravity 10 1 instance 1 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.217(d)(9)(i): The employer did not establish a die setting procedure for mechanical power press(es)  that would ensure compliance with 29 CFR 1910.217(c):    a) The employer did not establish a die setting procedures to insure compliance with paragraph B & C of 29 CFR 1910.217.
Recent events (1)
  • — Z (S) $0

1910.217 E01 I

Serious Gravity 10 2 instances 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.217(e)(1)(i): A program of periodic and regular inspections of mechanical power press(es) was not established and followed to ensure that all parts, auxiliary equipment and safeguards were in a safe operating condition and adjustment:    a) The employer did not establish a program of periodic and regular inspections of their mechanical power presses.
Recent events (1)
  • — Z (S) $0

1910.217 E01 II

Serious Gravity 10 2 instances 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.217(e)(1)(ii): Mechanical power press(es) were not inspected and tested at least weekly to determine the condition of the clutch/brake mechanism, antirepeat feature, and single stroke mechanism of mechanical power press(es).      a) The employer did not establish a program of weekly inspections of their mechanical power presses.
Recent events (1)
  • — Z (S) $0

1910.219 B01

Serious Gravity 10 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(b)(1): Flywheel(s) with parts seven (7) feet or less above floor(s) or platform(s) were not guarded in accordance with the requirements specified in 29 CFR 1910.219(b)(1)(i) through (b)(1)(iv):    a) Press Department - Whitney and Jensen model #130, serial #A1121, full revolution punch press, had a flywheel not completely guarded on the inside of the press.
Recent events (1)
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Pulleys, with parts of which are seven (7) feet or less from the floor or working platform, were not guarded in accordance with the standards specified in paragraphs (m) and (o) of this section:      a) Spinning Area - The employer had a Spinning Machine #1, that did not have the belt and pulley completely guarded to prevent contact with the moving parts.
Recent events (1)
  • — Z (S) $0

1910.219 E03 I

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(3)(i): Vertical and inclined belts were not enclosed by guards conforming to standards in paragraphs (m) and (o) of this section:    a) Spinning Area - The employer had a Spinning Machine #1, that did not have the belt and pulley completely guarded to prevent contact with the moving parts.
Recent events (1)
  • — Z (S) $0

1910.253 B02 II

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(2)(ii): Assigned storage spaces for cylinders was not located away from elevators, stairs, and gangways, or where cylinders could not be knocked over or damaged by passing or falling objects, or subject to tampering by unauthorized persons:       a) Press Department - Oxygen and Hydrogen Compressed cylinder tanks in storage were not secured from physical damage by passing or falling objects.
Recent events (1)
  • — Z (S) $0

1910.253 B04 III

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.253(b)(4)(iii): Oxygen cylinders in storage were not separated from fuel-gas cylinders or combustible materials (especially oil or grease), a minimum distance of 20 feet (6.1 m) or by a noncombustible barrier at least 5 feet (1.5 m) high having a fire-resistance rating of at least one-half hour:     a) Press Department - Oxygen cylinder tanks were stored side by side with Hydrogen cylinder tanks.
Recent events (1)
  • — Z (S) $0

1910.305 G02 III

Other-than-serious 1 instance 2 exposed
Issued
Jan 16, 2013
Abate by
Feb 12, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii): Flexible cords and cables were not connected to devices and fittings so that strain relief was provided will prevent pull from being directly transmitted to joints or terminal screws:     a) Press Department - There was an electrical cable cord that was detached from the end of the electrical box powering the Rouselle Full Revolution Power Press.        b) Press Department - There was a power cord detached from the end of the foot pedal powering the punch hole maker.
Recent events (1)
  • — Z (O) $0

View ALL Spun Metal Products, L.L.C.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337031983.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.