Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ROYAL CONSTRUCTION GROUP

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of ROYAL CONSTRUCTION GROUP in 1803 OAK POND, RUSKIN, FL 33571 (NAICS 238140). OSHA activity number 337032585.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Royal Construction Group — free Get an email when a new federal OSHA severe-injury report for Royal Construction Group is published. One employer, no account, unsubscribe in one click.
Site address
1803 OAK POND
City
RUSKIN
State
FL
ZIP
33571
Mailing
5891 SO MILITARY TRAIL # 5A UNIT # 417, LAKE WORTH, FL 33463
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
9
Ownership type
A

9 citations on file for this inspection.

1926.451 C02

Serious Gravity 10 1 instance 7 exposed
Issued
Dec 28, 2012
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:      (a)The scaffold system used at the construction of a residence at 1803 Oak Pond Court, Ruskin Florida was erected without mud sills on the north part of house, as observed on or about 10/23/12.
Recent events (1)
  • — Z (S) $2800

1926.451 F03

Serious Gravity 10 1 instance 7 exposed
Issued
Dec 28, 2012
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(f)(3):  Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity:    (a) the scaffold system used at the construction of a residence at 1803 Oak Pond Court, Ruskin Florida was not inspected by a competent person and had numerous deficiencies that compromised its structural integrity such as but not limited to, inadequate foundation, missing guardraills, no ladder for access and inadequate working surfaces, as observed on or about 10/23/2012.
Recent events (1)
  • — Z (S) $2800

1926.451 F07

Serious Gravity 10 1 instance 7 exposed
Issued
Dec 28, 2012
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.451(f)(7):  Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person.    (a)The scaffold system used at the construction of a residence at 1803 Oak Pond Court, Ruskin Florida was erected in the absence of a competent person and had numerous deficiencies such as but not limited to, missing baseplates, guardraills, ladder for access and fully planked, as observed on or about 10/23/2012. Employees were exposed to falls that ranged from 7 feet 6 inches up to 14 feet 4 inches while applying stucco.
Recent events (1)
  • — Z (S) $2800

1926.454 B

Serious Gravity 10 1 instance 7 exposed
Issued
Dec 28, 2012
Penalty
Initial $2,800 · Current $2,800
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question.    a) The employees observed working on a scaffold system used at the construction of a residence at 1803 Oak Pond Court, Ruskin Florida did not receive training on the nature of scaffold hazards, procedures for erecting, disassembling, moving, operating, repairing, inspecting, and maintaining the type of scaffold used, as observed on or about 10/23/12.
Recent events (1)
  • — Z (S) $2800

1926.451 B01

Repeat Gravity 10 1 instance 7 exposed
Issued
Dec 28, 2012
Penalty
Initial $5,600 · Current $5,600
29 CFR 1926.451(b)(1):  Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii):    a) Portions of the southwest and northeast sections of the scaffold system used at the construction of a residence at 1803 Oak Pond Court, were not fully planked. As observed on or about 10/23/12, employees were exposed to falls that ranged from 7 feet, 6 inches to 14 feet 4 inches while applying stucco.    The Royal Construction Group was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.451(b)(1), which was contained in OSHA inspection number 316282276, citation number 1, item number 1 and was affirmed as a final order on 03-23-2012, with respect to a workplace located at 5909 Egret Landing, Riverview, FL.
Recent events (1)
  • — Z (R) $5600

1926.451 B02

Repeat Gravity 10 1 instance 7 exposed
Issued
Dec 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(2):  Scaffold platforms and walkways were not at least 18 inches wide:    (a) On or about 10/23/12, employees were observed working on 9 inch wood planks at the construction of a residence at 1803 Oak Pond Court, Ruskin Florida. The employees were exposed to falls that ranged from 7 feet 6 inches up to 14 feet 4 inches while applying stucco.    The Royal Construction Group was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.451(b)(1), which was contained in OSHA inspection number 316282276, citation number 1, item number 1 and was affirmed as a final order on 03-23-2012, with respect to a workplace located at 5909 Egret Landing, Riverview, FL.
Recent events (1)
  • — Z (R) $0

1926.451 B04

Repeat Gravity 10 1 instance 7 exposed
Issued
Dec 28, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(b)(4):  Each end of a platform, not cleated or otherwise restrained by hooks or equivalent means, did not extend over the centerline of its support at least 6 inches (15 cm)    (a) On or about 10/23/12, employees were observed working at the construction of a residence at 1803 Oak Pond Court, Ruskin Florida. The ends of the wood planks used in the north side of the scaffold system extended less than 3 inches over the centerline of its support and exposed the employees to falls that ranged from 7 feet 6 inches up to 14 feet 4 inches while applying stucco.    The Royal Construction Group was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.451(b)(1), which was contained in OSHA inspection number 316282276, citation number 1, item number 1 and was affirmed as a final order on 03-23-2012, with respect to a workplace located at 5909 Egret Landing, Riverview, FL.
Recent events (1)
  • — Z (R) $0

1926.451 E01

Repeat Gravity 10 1 instance 7 exposed
Issued
Dec 28, 2012
Penalty
Initial $5,600 · Current $5,600
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used.  Crossbraces were used as a means of access.    a) No safe to access the scaffold was provided to the scaffold system used at the construction of a residence at 1803 Oak Pond Court. As observed on or about 10/23/12, the employees using the crossbraces as access were exposed to falls that ranged from 7 feet, 6 inches to 14 feet 4 inches while applying stucco.    The Royal Construction Group was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.451(b)(1), which was contained in OSHA inspection number 316282276, citation number 1, item number 1 and was affirmed as a final order on 03-23-2012, with respect to a workplace located at 5909 Egret Landing, Riverview, FL.
Recent events (1)
  • — Z (R) $5600

1926.451 G01

Repeat Gravity 10 1 instance 7 exposed
Issued
Dec 28, 2012
Penalty
Initial $5,600 · Current $5,600
29 CFR 1926.451(g)(1):  Each employee on a scaffold more than 10 feet above a lower level were not protected from falling to that lower level.    a) The scaffold system used at the construction of a residence at 1803 Oak Pond Court, Ruskin Florida lacked side guardrails on the top tier of the southwest and northeast corners. As observed on or about 10/23/12, employees were exposed to falls of approximately 14 feet 4 inches while applying stucco.    The Royal Construction Group was previously cited for a violation of this occupational safety and health standard or its equivalent standard, 29 CFR 1926.451(b)(1), which was contained in OSHA inspection number 316282276, citation number 1, item number 1 and was affirmed as a final order on 03-23-2012, with respect to a workplace located at 5909 Egret Landing, Riverview, FL.
Recent events (1)
  • — Z (R) $5600

View Royal Construction Group's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337032585.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.