OSHA Inspection: WEBGISTIX CORPORATION

Complaint inspection · Safety discipline

On , OSHA opened a complaint safety inspection of WEBGISTIX CORPORATION in 2251 CONSTITUTION AVENUE, OLEAN, NY 14760 (NAICS 493110). OSHA activity number 337046783.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Webgistix Corporation — free Get an email when a new federal OSHA severe-injury report for Webgistix Corporation is published. One employer, no account, unsubscribe in one click.
Site address
2251 CONSTITUTION AVENUE
City
OLEAN
State
NY
ZIP
14760
Mailing
2251 CONSTITUTION AVENUE, OLEAN, NY 14760
Inspection type
Complaint (B)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
493110
Employees
18
Ownership type
A

7 citations on file for this inspection.

1910.23 E01

Serious Gravity 5 1 instance 10 exposed
Issued
Dec 18, 2012
Abate by
Jan 20, 2013
Penalty
Initial $2,380 · Current $1,500 Reduced
29 CFR 1910.23(e)(1):     Standard railing(s) did not consist of top rail, intermediate rail and/or posts and/or did not have a vertical height of 42 inches (106.7 cm) nominal from upper surface of top rail to floor, platform runway, or ramp level:    a) On or about 10/24/12, in the warehouse, a mezzanine's railing had a vertical height of 34 inches and it did not have an intermediate rail.       ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1500
  • — Z (S) $2380

1910.37 A03

Serious Gravity 1 1 instance 10 exposed
Issued
Dec 18, 2012
Penalty
Initial $1,785 · Current $1,000 Reduced
29 CFR 1910.37(a)(3):     Exit route(s) were not kept free and unobstructed:    a) On or about 10/24/12, in the warehouse area, access to an emergency exit route and an exit door was blocked by boxes with merchandise.     NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1785

1910.157 C01

Serious Gravity 1 1 instance 10 exposed
Issued
Dec 18, 2012
Abate by
Jan 20, 2013
Penalty
Initial $1,785 · Current $1,000 Reduced
29 CFR 1910.157(c)(1):     Portable fire extinguishers were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries:      a) On or about 10/24/12, in the warehouse area, access to two fire extinguishers was blocked by boxes with merchandise.     ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1785

1910.157 G02

Serious Gravity 1 1 instance 10 exposed
Issued
Dec 18, 2012
Abate by
Jan 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(g)(2):     The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire fighting was not provided to all employees upon initial employment, and at least annually thereafter:      a) On or about 10/24/12, in the warehouse area, employer did not provide an educational program about fire extinguisher use and fire hazards to employees.     ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 1 1 instance 10 exposed
Issued
Dec 18, 2012
Abate by
Jan 20, 2013
Penalty
Initial $1,785 · Current $1,000 Reduced
29 CFR 1910.305(b)(1)(ii):     Unused openings in boxes, cabinets, or fittings were not effectively closed:    a) On or about 10/24/12, in the warehouse areas, an electrical box light switch mounted on a support beam had a missing knockout.      ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $1000
  • — Z (S) $1785

1910.305 B02 I

Serious Gravity 1 1 instance 10 exposed
Issued
Dec 18, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.305(b)(2)(i):     Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy:    a) On or about 10/24/12, in the warehouse areas, an electrical box light switch mounted on a wall had a broken cover exposing energized wiring.     NO ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.176 B

Other-than-serious 1 instance 10 exposed
Issued
Dec 18, 2012
Abate by
Jan 20, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.176(b):     Storage of material created a hazard:    a) On or about 10/24/12, in the warehouse areas, cardboard materials were stored in an unstable manner due to the use of broken pallets and unsafe pallet stacking techniques.      ABATEMENT CERTIFICATION REQUIRED
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Webgistix Corporation's full OSHA safety record →