Safety Incidents OSHA Severe Injury Reports · 2015–2025
2,004,209Inspections Most recent open 2026-07-13 Last loaded 2026-07-17

OSHA Inspection: PARTHENON HOSPITALITY, LTD

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of PARTHENON HOSPITALITY, LTD in 3100 I 40 W, AMARILLO, TX 79102 (NAICS 721110). OSHA activity number 337051387.

Watch Parthenon Hospitality, LTD — free Get an email when a new federal OSHA severe-injury report for Parthenon Hospitality, LTD is published. One employer, no account, unsubscribe in one click.
Site address
3100 I 40 W
City
AMARILLO
State
TX
ZIP
79102
Mailing
3100 I 40 W, AMARILLO, TX 79102
Inspection type
Programmed Related (J)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
721110
Employees
141
Ownership type
A

5 citations on file for this inspection.

1910.22 A01

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2430.00 · Current $2430.00
29 CFR 1910.22(a)(1):  Place(s) of employment, passageways, storerooms, and service rooms were not kept clean, orderly and in a sanitary condition:  On October 24, 2012,  and at times prior thereto, at the Parthenon Hospitality, Ltd dba Ambassador Hotel located at 3100 I-40 West, Amarillo, Texas 79102, the employer failed to ensure that the work place was kept in an orderly manner.  Thus, the employees were exposed to slips/trips and fall hazards.
Recent events (1)
  • — Z (S) $2430

1910.22 A02

Serious Gravity 1 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $2430.00 · Current $2430.00
29 CFR 1910.22(a)(2):  The floor of every workroom was not maintained in a clean and, so far as possible, a dry condition. Drainage areas were not maintained, or other dry standing places should be provided where practicable.  On October 24, 2012, and at times prior thereto, at the Parthenon Hospitality, Ltd dba Ambassador Hotel located at 3100 I-40 West, Amarillo, Texas 79102, the employer did not ensure the Boiler Room work area was maintained in a dry and sanitary condition.  Employees were exposed to slip and fall hazards.
Recent events (1)
  • — Z (S) $2430

1910.303 F02

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3240.00 · Current $3240.00
29 CFR 1910.303(f)(2):  Services, feeders, and branch circuits. Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, were not legibly marked to indicate its purpose, unless located and arranged so the purpose is evident:  On October 24, 2012, and at times prior thereto, at the Parthenon Hospitality, Ltd dba Ambassador Hotel, located at 3100 I-40 West, Amarillo, Texas 79102, the employer did not ensure that the junction boxes were labeled or properly labeled for their purpose:      a.  Pool Room junction box,      b.  First Floor junction box,      c.  Third Floor junction box,      d.  Seventh Floor junction box,      e.  Nineth Floor junction box.
Recent events (1)
  • — Z (S) $3240

1910.305 B03 II

Serious Gravity 5 5 instances 6 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.305(b)(3)(ii):  Employer did not ensure that all pull and junction boxes were closed by suitable covers securely fastened in place:  On October 24, 2012, and at times prior thereto, at the Parthenon Hospitality Ltd. dba Ambassador Hotel, located at 3100 I-40 West, Amarillo, Texas 79102, the employer did not ensure that the covers to the junction boxes were closed with a cover:      a.  Pool Room cover was missing on junction box,      b.  First Floor electrical room door to junction box was open,      c.  Third Floor electrical room door to junction box was open,      d.  Seventh Floor electrical room door to junction box was open,      e.  Nineth Floor electrical room door to junction box was open.
Recent events (1)
  • — Z (S) $0

1910.305 J02 VI

Serious Gravity 5 1 instance 6 exposed
Issued
Abate by
Penalty
Initial $3240.00 · Current $3240.00
29 CFR 1910.305(j)(2)(vi):  Receptacle installed in a wet location where the product intended to be plugged into it was not attended while in use (for example, sprinkler system controllers, landscape lighting, and holiday lights) shall have an enclosure that is weatherproof with the attachment plug cap inserted or removed:  On October 24, 2012, and at times prior thereto at the Parthenon Hospitality Ltd. dba Ambassador Hotel, located at 3100 I-40 West, Amarillo, Texas 79102, the employer did not ensure the outlets on the Third Floor roof where flexible cords were connected were enclosed, protected from weather.  Employees were exposed to electrical shock.
Recent events (1)
  • — Z (S) $3240

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337051387.