OSHA Inspection: HAWTHORNE PACIFIC CORPORATION

Federal Agency inspection · Safety discipline

On , OSHA opened a federal Agency safety inspection of HAWTHORNE PACIFIC CORPORATION in 470 HANA HWY, KAHULUI, HI 96732 (NAICS 811310). OSHA activity number 337052591.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Hawthorne Pacific Corporation — free Get an email when a new federal OSHA severe-injury report for Hawthorne Pacific Corporation is published. One employer, no account, unsubscribe in one click.
Site address
470 HANA HWY
City
KAHULUI
State
HI
ZIP
96732
Mailing
94-025 FARRINGTON HWY., WAIPAHU, HI 96797
Inspection type
Federal Agency (M)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
811310
Employees
15
Ownership type
A

17 citations on file for this inspection.

1910.101 B

Other-than-serious 2 instances 5 exposed
Issued
Apr 16, 2013
Abate by
May 3, 2013
Penalty
Initial $4,000 · Current $2,000 Reduced
29 CFR 1910.101(b):  Section 3.4.4, of the Compressed Gas Association Pamphlet P-1 1965, as adopted by 29 CFR 1910.101(b):  Compressed gas cylinder(s) were not properly supported to prevent them from being knocked over:     On or about January 18th, 2013:     a) Two compressed propane gas cylinders used to power industrial fork lifts were being stored inside the Parts Warehouse on the North wall without being secured.     b) A compressed propane gas cylinder was being stored between the roll-up doors in the Rebuild shop without being secured.
Recent events (2)
  • — I (O) $2000
  • — Z (S) $4000

1910.145 F03

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 16, 2013
Abate by
May 10, 2013
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.145(f)(3): Tags were not used as a means to prevent accidental injury or illness to employees who were exposed to hazardous or potentially hazardous conditions, equipment or operations which were out of the ordinary, unexpected or not readily apparent:    Or about October 23, 2012, the keys for a truck mounted crane were accessible to all employees.  The crane was not tagged to identify known hazardous conditions, including an inoperable Load Moment Indicator.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.151 C

Other-than-serious 2 instances 4 exposed
Issued
Apr 16, 2013
Abate by
May 10, 2013
Penalty
Initial $4,000 · Current $3,000 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:      On January 18th, 2013:    In the battery charging area, access to an eye wash station was blocked by debris and was not within the immediate area of the serving operation.
Recent events (2)
  • — I (O) $3000
  • — Z (S) $4000

1910.180 D05 II

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 16, 2013
Abate by
May 3, 2013
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.180(d)(5)(ii): A crane which was idle for a period of six months was not given a complete inspection conforming with requirements of paragraphs (d) (3) and (4) of this section and paragraph (g)(2)(ii) of this section before placing in service:  On or about October 23, 2012, a truck crane which had not been used since May 13, 2011, and had not received a complete inspection since September 6, 2011, was placed in service and was not given a complete inspection prior to use after sitting idle for over six months.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.180 D06

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 16, 2013
Abate by
May 3, 2013
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.180(d)(6): Monthly, dated and signed inspection records and reports for truck crane(s) were not provided for critical items such as (but not limited to) brakes, crane hooks and ropes:   On or about October 24, 2012, monthly inspection records of critical items such as but not limited to brakes, crane hooks and ropes were not completed nor available for the National 900 series truck crane.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.180 H03 IX

Serious Gravity 10 1 instance 6 exposed
Issued
Apr 16, 2013
Abate by
May 3, 2013
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.180(h)(3)(ix): Outriggers were not used when required to handle a load at a given radius:  On or about October 23, 2012, an industrial boom truck crane was used with the main outriggers not extended, as required by the crane's operators' manual, which allowed the crane to tip over.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 16, 2013
Abate by
May 3, 2013
Penalty
Initial $6,000 · Current $6,000
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    On or about January 18th, 2013, in the Rebuild Shop, employees were exposed to rotating part hazards while operating the vertical drill press.
Recent events (2)
  • — I (S) $6000
  • — Z (S) $6000

1910.215 A04

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 16, 2013
Abate by
May 3, 2013
Penalty
Initial $6,000 · Current $4,000 Reduced
29 CFR 1910.215(a)(4): Work rest(s) on grinding machinery were not adjusted closely to the wheel with a maximum opening of one-eight inch:    On or about January 18th, 2013, in the Rebuild Shop, where the left work rest was missing and the right work rest of the bench grinder was not adjusted closely to the wheel.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $6000

1910.215 B09

Serious Gravity 5 1 instance 4 exposed
Issued
Apr 16, 2013
Abate by
May 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.215(b)(9): The distance between the abrasive wheel periphery(s) and the adjustable tongue or the end of the safety guard peripheral member at the top exceeded one fourth inch:  On or about January 18th, 2013, in the Rebuild Shop, where the left and right tongue guards of the bench grinder were not adjusted as required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Serious Gravity 5 3 instances 12 exposed
Issued
Apr 16, 2013
Abate by
May 3, 2013
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.303(f)(2): Each service, feeder, and branch circuit, at its disconnecting means or over-current device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident.    On or about January 18, 2013, all disconnecting means or over-current devices on the electrical panels on the West and North walls of the Parts Warehouse and Rebuild Shop were not legibly marked to indicate their purpose when the purpose was not evident.
Recent events (2)
  • — I (S) $5000
  • — Z (S) $5000

1910.303 G01

Serious Gravity 5 1 instance 12 exposed
Issued
Apr 16, 2013
Abate by
May 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:   On or about January 18, 2013, access to an electrical control panel on the west wall of the parts warehouse was blocked.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 5 1 instance 5 exposed
Issued
Apr 16, 2013
Abate by
Apr 16, 2013
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed.      On or about January 18, 2013, an electrical control panel on the West wall of the parts warehouse had an unused opening on the lower left hand side of the cabinet.
Recent events (2)
  • — I (S) $0
  • — Z (S) $5000

1910.305 B02 I

Serious Gravity 5 3 instances 8 exposed
Issued
Apr 16, 2013
Abate by
Apr 16, 2013
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1910.305(b)(2)(i): Each outlet box in completed installations did not have a cover, faceplate, or fixture canopy.        On or about October 24, 2012:    a) On the North wall of the Safety Manager's office, an electrical outlet faceplate was missing.    b) On the West wall of the Safety Manager's office, an electrical outlet faceplate was missing.    c) On the North wall of the Parts office area, an electrical outlet faceplate was missing.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4000

1910.334 A02 II

Serious Gravity 5 1 instance 3 exposed
Issued
Apr 16, 2013
Abate by
May 3, 2013
Penalty
Initial $4,000 · Current $4,000
29 CFR 1910.334(a)(2)(ii): When there was a defect or evidence of damage that could have exposed an employee to injury, the defective or damaged item was not removed from service:      On or about January 18, 2013, a table-top drill press with a damaged cord was in use in the Rebuild Shop.
Recent events (2)
  • — I (S) $4000
  • — Z (S) $4000

1910.212 B

Serious Gravity 5 2 instances 4 exposed
Issued
Apr 16, 2013
Abate by
May 3, 2013
Penalty
Initial $4,000 · Current $0 Reduced
29 CFR 1910.212(b): Machine(s) designed for fixed location(s) were not securely anchored to prevent walking or moving.      On or about January 18, 2013 in the Rebuild Shop:    a) A pedestal grinder was not secured to the concrete floor.    b) A drill press was sitting permanently on a metal table and not secured or anchored to the table top.
Recent events (2)
  • — I (S) $0
  • — Z (S) $4000

1910.37 B05

Other-than-serious 2 instances 15 exposed
Issued
Apr 16, 2013
Abate by
Apr 26, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.37(b)(5): Each doorway or passage along an exit access that could be mistaken for an exit was not marked "Not an Exit" or similar designation, or be identified by a sign indicating its actual use:  On or about January 18th, 2013:  a) Several doors in the Rebuild Shop could be mistaken for an Exit and were not labeled as "Not an Exit" or indicating its actual use.  b) On the second floor of the Parts Warehouse, a door leading into the attic was not labeled as "Not an Exit" or indicating its actual use, and could be mistaken for an emergency exit and employees could be trapped.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.157 C01

Other-than-serious 2 instances 6 exposed
Issued
Apr 16, 2013
Abate by
May 3, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.157(c)(1): Portable fire extinguishers used inside the building were not mounted, located and identified so that they were readily accessible without subjecting the employees to injuries.    On or about January 18, 2013:    a) On the North wall of the Rebuild Shop, a fire extinguisher located behind a drill press was not mounted.    b) On the West side of the Rebuild Shop, a fire extinguisher adjacent to the roll-up door was sitting on the concrete floor and was not mounted or secured.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337052591.