Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: CORESLAB STRUCTURES (MIAMI) INC.

Programmed Related inspection · Safety discipline

On , OSHA opened a programmed Related safety inspection of CORESLAB STRUCTURES (MIAMI) INC. in 3800 NW 115TH AVE., DORAL, FL 33178 (NAICS 327390). OSHA activity number 337061386.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Coreslab Structures (Miami) INC. — free Get an email when a new federal OSHA severe-injury report for Coreslab Structures (Miami) INC. is published. One employer, no account, unsubscribe in one click.
Site address
3800 NW 115TH AVE.
City
DORAL
State
FL
ZIP
33178
Mailing
10501 NW 121 WAY, MEDLEY, FL 33178
Inspection type
Programmed Related (J)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
327390
Employees
191
Ownership type
A

1 citation on file for this inspection.

5(a)(1)

Serious Gravity 10 1 instance 120 exposed
Issued
Apr 8, 2013
Abate by
Apr 25, 2013
Penalty
Initial $7,000 · Current $7,000
OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees when they were exposed to struck-by and caught-in-between hazards:     On or about 10/10/2012, at the above addressed jobsite, employees were exposed to the risk of being struck-by collapsing pre-cast structural members due to not ensuring that the base of column B-3 was properly grouted.    Among other methods, one feasible and acceptable abatement method to correct this hazard is to follow the grout application instructions as per Coreslab Erection Drawings E0.0 General Notes, Section 3.4 Grout and Solar Erector's erection procedure in the column section, item # 4.    NOTE: ABATEMENT CERTIFICATION AND DOCUMENTATION IS REQUIRED FOR THIS ITEM.
Recent events (2)
  • — I (S) $7000
  • — Z (S) $7000

View Coreslab Structures (Miami) INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337061386.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.