KIRKWOOD, NY —
OSHA Inspection: KC CONSTRUCTION INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of KC CONSTRUCTION INC. in 52 SERVICE ROAD, KIRKWOOD, NY 13795 (NAICS 238160). OSHA activity number 337073589.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- KC CONSTRUCTION INC.
- Site address
- 52 SERVICE ROAD
- City
- KIRKWOOD
- State
- NY
- ZIP
- 13795
- Mailing
- 2310 NORTH STREET, ENDWELL, NY 13760
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238160
- Employees
- 20
- Ownership type
- A
Citations
6 citations on file for this inspection.
1926.501 B13
- Issued
- Nov 21, 2012
- Abate by
- Dec 4, 2012
- Penalty
- Initial $2,400 · Current $0 Reduced
General-duty citation text
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) 52 Service Road Residential Roof - On or about October 25, 2012 - Employees were installing wood sheathing over the existing sheathing on a residential roof with a pitch of 10 inches on 12 inches without the use of conventional fall protection. Employees were exposed to a fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $2400
1926.404 B01 II
- Issued
- Nov 21, 2012
- Abate by
- Dec 4, 2012
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection. a) 52 Service Road Residential Home - On or about 25 October, 2012 - Employees were installing new roof sheathing and using a compressor that was powered through an extension cord that was not connected to a ground fault circuit interrupter. Employees were exposed to an electric shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1926.404 F06
- Issued
- Nov 21, 2012
- Abate by
- Dec 4, 2012
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) 52 Service road residential home - On or about 25 October, 2012 - Employees were using a compressor that did not have a ground prong attached while in use. Employees were exposed to an electric shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
1926.403 B02
- Issued
- Nov 21, 2012
- Abate by
- Dec 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: a) 52 Service road residential home - On or about 25 October, 2012 - Employees were using a compressor that was not grounded and was not in accordance with manufacturers labeling on safe operation. Employees were exposed to an electrical shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.405 G02 IV
- Issued
- Nov 21, 2012
- Abate by
- Dec 4, 2012
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) 52 Service Road Residential Home - On or about October 25, 2012 - Employees were installing new roof sheathing and using a compressor that was powered through an extension cord that was not provided with strain relief to prevent pull from being directly transmitted to joints or terminal screws. Employees were exposed to an electrical shock hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $0
1926.25 A
- Issued
- Nov 21, 2012
- Abate by
- Dec 4, 2012
- Penalty
- Initial $1,200 · Current $0 Reduced
General-duty citation text
29 CFR 1926.25(a): During the course of construction, alteration, or repairs, debris was not kept cleared from work areas, passageways, and stairs, in and around buildings or other structures: a) 52 Service road residential home - On or about 25 October, 2012 - The old asphalt roofing shingles that were removed off the roof were not disposed of, and the work area was not kept clear around the base of the building. Employees were working directly above the debris pile. Employees were exposed to a fall hazard.
Recent events (2)
- — I (S) $0
- — Z (S) $1200
More inspections at KC Construction INC.
View KC Construction INC.'s full OSHA safety record →
More inspections in this industry (NAICS 238160)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337073589.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.