Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: UNIVERSAL ELECTRIC FOUNDRY, INC.

Planned inspection · Health discipline

On , OSHA opened a planned health inspection of UNIVERSAL ELECTRIC FOUNDRY, INC. in 1523 W. HUBBARD ST., CHICAGO, IL 60642 (NAICS 331528). OSHA activity number 337075808.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Universal Electric Foundry, INC. — free Get an email when a new federal OSHA severe-injury report for Universal Electric Foundry, INC. is published. One employer, no account, unsubscribe in one click.
Site address
1523 W. HUBBARD ST.
City
CHICAGO
State
IL
ZIP
60642
Mailing
1523 W. HUBBARD ST., CHICAGO, IL 60642
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
A
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331528
Employees
24
Ownership type
A

7 citations on file for this inspection.

1910.23 E05 II

Serious Gravity 5 1 instance 25 exposed
Issued
Jan 8, 2013
Abate by
Feb 26, 2013
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.23(e)(5)(ii):     The height of handrails shall be not more than 34 inches nor less than 30 inches from upper surface of handrail to surface of tread in line with face of riser or to surface of ramp.      a. First Floor/Metal Stairway leading to the Patterns Storage Room - On or about November 6, 2012, employees were required to retrieve metal molds using a staircase with handrails that measured (21) twenty one inches in height. Employees were thereby exposed to fall hazards.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.179 J02 I

Other-than-serious 1 instance 24 exposed
Issued
Jan 8, 2013
Abate by
Feb 26, 2013
Penalty
Initial $2,380 · Current $0 Reduced
29 CFR 1910.179(j)(2)(i):     Frequent Inspections - All functional operating mechanisms for maladjustment interfering with proper operation. Daily.    a. Molding Operations Area - On or about October 29, 2012, the employer did not conduct daily inspections of the overhead crane systems to move foundry equipment ( Gantry/Budgit - 1 Ton & Jib/Arrow - 1 Ton). The operating mechanism for the (Budgit) crane's hook had its safety latch missing. Employees were thereby exposed to struck by hazards.
Recent events (2)
  • — I (O) $0
  • — Z (S) $2380

1910.305 A02

Serious Gravity 5 2 instances 24 exposed
Issued
Jan 8, 2013
Abate by
Feb 26, 2013
Penalty
Initial $2,380 · Current $1,190 Reduced
29 CFR 1910.305(a)(2):     Temporary wiring. Except as specifically modified in this paragraph, all other requirements of this subpart for permanent wiring shall also apply to temporary wiring installations.    a. Foundry Operations Areas - On or about October 29, 2012, electrical extension cords were being use as temporary wiring. Employees were thereby potentially exposed to electrical hazards. The areas where these extension cords observed were the following;    1. In the molding area an extension cord was used as temporary wiring to power a rail trolley.
Recent events (2)
  • — I (S) $1190
  • — Z (S) $2380

1910.305 G02 III

Serious Gravity 1 1 instance 24 exposed
Issued
Jan 8, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.305(g)(2)(iii):     Flexible cords and cables shall be connected to devices and fittings so that strain relief is provided that will prevent pull from being directly transmitted to joints or terminal screws.    1. Floor Conveyor Area - On or about October 29, 2012, the flexible cord for the conveyor's motor (480 volts) was loose from its metal casing assembly. Employees were thereby exposed to electrical hazards.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.1018 K01

Other-than-serious 1 instance 5 exposed
Issued
Jan 8, 2013
Abate by
Feb 26, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 0260

29 CFR 1910.1018(k)(1):     Housekeeping Surfaces. All surfaces shall be maintained as free as practicable of accumulations of inorganic arsenic.    a. First Floor/Grinding Station - On or about November 6, 2012, employees were required to work in areas that were not maintained as free as practicable of accumulations of inorganic arsenic. Employees were exposed to the health hazards of working with inorganic arsenic. The following area was found with accumulations of arsenic;    1. First Floor/ Grinding Station - floor sweepings were found to contained 0.0042 % of inorganic arsenic.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1025 L01 I

Other-than-serious 1 instance 23 exposed
Issued
Jan 8, 2013
Abate by
Feb 26, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 1591

29 CFR 1910.1025(l)(1)(i):     Each employer who has a workplace in which there is a potential exposure to airborne lead at any level shall inform employees of the content of Appendices A and B of this regulation.    a. First Floor/Furnace Area - On or about November 6, 2012, employees required to work in areas where there was a exposure to lead were not inform of the lead standard and its appendices A and B. Employees were exposed to the hazards associated with lead.
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.1026 J01 I

Other-than-serious 2 instances 10 exposed
Issued
Jan 8, 2013
Abate by
Feb 26, 2013
Penalty
Initial $0 · Current $0

Hazardous substances 0689

29 CFR 1910.1026(j)(1)(i):       Housekeeping - The employer shall ensure that all surfaces are maintained as free as practicable of accumulations of chromium (VI).    a. 2nd Floor/Employee's Lunch Room - On or about November 6, 2012, the employer had work surfaces that were not maintained as free as practicable of accumulations of chromium (VI).    1. The top surface area (center location) of the lunch table contained 0.0956 micrograms of chromium (VI).    2. The refrigerator (Hot Point) door's lower handle contained 0.1304 micrograms of chromium (VI).
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View Universal Electric Foundry, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337075808.