Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: GM NAMEPLATE, INC.

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of GM NAMEPLATE, INC. in 27 PRODUCTION DR., DOVER, NH 03820 (NAICS 336399). OSHA activity number 337098990.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch GM Nameplate, INC. — free Get an email when a new federal OSHA severe-injury report for GM Nameplate, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
GM NAMEPLATE, INC.
Site address
27 PRODUCTION DR.
City
DOVER
State
NH
ZIP
03820
Mailing
27 PRODUCTION DR., DOVER, NH 03820
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
336399
Employees
500
Ownership type
A

7 citations on file for this inspection.

1910.147 C04 I

Other-than-serious 5 instances 3 exposed
Issued
Jan 28, 2013
Abate by
Feb 1, 2013
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.147(c)(4)(i):  Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section:    a.  Site - The employer did not develop, implement and utilize a lockout procedure for the Press Master #5(Model CFP-12T S/N 0800420-90) power press.     b.  Site - The employer did not develop, implement and utilize a lockout procedure for the Press Master (Model CFP-12T S/N 0800420-04) power press.     c.  Site -The employer did not develop, implement and utilize a lockout procedure for the Greennerd Press (Model HPB-10 S/N 99T5746) power press.     d.  Site - The employer did not develop, implement and utilize a lockout procedure for the Power Press (number D6).     e.  Site - The employer did not develop, implement and utilize a lockout procedure for the Power Press (number D8).
Recent events (3)
  • — C (S) $5000
  • — F (O) $5000
  • — Z (S) $5000

1910.212 A01

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 28, 2013
Abate by
Feb 1, 2013
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.212(a)(1):  One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    Instance a. Site - Machine guarding was not provided to protect employees from the in-going nip point on the   laminator #3 machinery rotating wheel.     Instance b. Site - Machine guarding was not provided to protect employees from the in-going nip point on the tape cutter machine rotating paper roll.
Recent events (3)
  • — C (S) $5000
  • — F (S) $5000
  • — Z (S) $5000

1910.212 A03 II

Serious Gravity 10 2 instances 2 exposed
Issued
Jan 28, 2013
Abate by
Feb 1, 2013
Penalty
Initial $7,000 · Current $7,000
29 CFR 1910.212(a)(3)(ii): Point of operation guards were not designed and constructed as to prevent the operator from having any part of their body in the danger zone during the operating cycle:    Instance a. Site - Point of operation guard was not provided at the flipping machine.     Instance b. Site - Point of operation guard was not provided at the tape cutting machine.
Recent events (3)
  • — C (S) $7000
  • — F (S) $7000
  • — Z (S) $7000

1910.217 B07 II

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 28, 2013
Abate by
Feb 1, 2013
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.217(b)(7)(ii):  Mechanical power press(es) using part revolution clutches were not provided with a red color stop control, which would immediately deactivate the clutch and apply the brake, override any other control, and require use of the operating (tripping) means which has been selected:    Instance a. The emergency stop control on the Press Master #5(model CFP-12T S/N 080-0420-90) power press was not accessible for the operator.     Instance b. The emergency stop control on the Press Master (model CFP-12T S/N 080-0420-04) power press was not accessible for the operator.     Instance c. The emergency stop control on the Greennerd Press (model HPB S/N 99T5746) power press was not accessible for the operator.
Recent events (3)
  • — C (S) $5000
  • — F (S) $5000
  • — Z (S) $5000

1910.219 C02 I

Serious Gravity 5 2 instances 2 exposed
Issued
Jan 28, 2013
Abate by
Feb 1, 2013
Penalty
Initial $5,000 · Current $5,000
29 CFR 1910.219(c)(2)(i):  All exposed part(s) of horizontal shafting seven (7) feet or less from floor or working platform were not protected by stationary casing(s) enclosing shafting completely or by trough(s) enclosing sides and top or sides and bottom of shafting:    Instance a. Site - The horizontal shaft on the Laminator # 3 was not adequately guarded on all sides to prevent employees from accidental contact during the rotation cycle.     Instance b. Site - The horizontal shaft on the flipping machine was not adequately guarded on all sides to prevent employees from accidental contact during the rotation cycle.
Recent events (3)
  • — C (S) $5000
  • — F (S) $5000
  • — Z (S) $5000

1910.219 C04

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 28, 2013
Abate by
Feb 1, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4): Projecting shaft ends.    a. Site - The protruding shaft end on the Laminator #3 was not guarded to prevent accidental contact during rotation cycle.
Recent events (3)
  • — C (S) $0
  • — F (S) $0
  • — Z (S) $0

1910.242 B

Other-than-serious 5 instances 5 exposed
Issued
Jan 28, 2013
Abate by
Feb 1, 2013
Penalty
Initial $5,000 · Current $0 Reduced
29 CFR 1910.242(b):  Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.:      a. Site - Compressed air utilized for cleaning purposes at employees' workstations was at 90 PSI.
Recent events (3)
  • — C (S) $5000
  • — F (O) $0
  • — Z (S) $5000

View GM Nameplate, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337098990.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.