ROME, NY —
OSHA Inspection: BARTELL MACHINERY SYSTEMS, L.L.C.
Planned inspection · Health discipline
At a glance
On , OSHA opened a planned health inspection of BARTELL MACHINERY SYSTEMS, L.L.C. in 6321 ELMER HILL ROAD, ROME, NY 13440 (NAICS 333319). OSHA activity number 337104798.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- BARTELL MACHINERY SYSTEMS, L.L.C.
- Site address
- 6321 ELMER HILL ROAD
- City
- ROME
- State
- NY
- ZIP
- 13440
- Mailing
- 6321 ELMER HILL ROAD, ROME, NY 13440
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Health
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 333319
- Employees
- 142
- Ownership type
- A
Citations
9 citations on file for this inspection.
1910.22 A01
- Issued
- Jan 25, 2013
- Penalty
- Initial $2,295 · Current $2,295
General-duty citation text
29 CFR 1910.22(a)(1): Place(s) of employment were not kept clean: a) Distrubtion Center Area, on or about 10/25/12: Explosive Wood Dust (Class II) was observed throughout the table saw floor area.
Recent events (3)
- — J (O) $2295
- — C (S) $2295
- — Z (S) $2295
1910.24 H
- Issued
- Jan 25, 2013
- Penalty
- Initial $2,295 · Current $2,295
General-duty citation text
29 CFR 1910.24(h): Standard railing(s) were not provided on the open side(s) of all fixed industrial stairway(s) and stair platform(s): a) Saw/Truck Pit Area, on or about 10/25/12: A flight of stairs with six risers did not have a handrail on the right side. b) Brake & Shear Area, on or about 10/25/12: A flight of stairs with six risers did not have a handrail on the left side.
Recent events (3)
- — J (O) $2295
- — C (S) $2295
- — Z (S) $2295
1910.106 E06 I
- Issued
- Jan 25, 2013
- Penalty
- Initial $3,060 · Current $0 Reduced
General-duty citation text
29 CFR 1910.106(e)(6)(i): Adequate precautions against the ignition of flammable vapors were not taken: : a) Paint Booth Flammable Storage Area, on or about 10/25/12: Employees dispense 105 Lacquer Thinner a Class 1B flammable material without grounding the 16 gallon container.
Recent events (3)
- — J (S) $0
- — C (S) $3060
- — Z (S) $3060
1910.106 E06 II
- Issued
- Jan 25, 2013
- Penalty
- Initial $0 · Current $2,142
General-duty citation text
29 CFR 1910.106(e)(6)(ii): Class I flammable liquid(s) were dispensed into containers without electrically interconnecting the nozzle and the container: a) Paint Booth Flammable Storage Area, on or about 10/25/12: Employees dispense 05 Lacquer Thinner a Class 1B flammable material from a 16 gallon drum to a secondary container with no means of electrically interconnecting the nozzle and the portable container.
Recent events (3)
- — J (S) $2142
- — C (S) $0
- — Z (S) $0
1910.107 B09
- Issued
- Jan 25, 2013
- Penalty
- Initial $2,295 · Current $2,295
General-duty citation text
29 CFR 1910.107(b)(9): A clear space of not less than 3 feet was not kept free from storage on all sides of paint booth(s): a) Spray Paint Booth, on or about 10/25/12: Combustible materials including but not limited to: wooden pallets; rack with miscellaneous parts stored on it and empty containers of lacquer thinner were observed on the right and left side of the paint booth.
Recent events (3)
- — J (O) $2295
- — C (S) $2295
- — Z (S) $2295
1910.107 G02
- Issued
- Jan 25, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.107(g)(2): Spraying area(s) were not kept free from the accumulation of deposits of combustible residues: a) Paint Booth Area, on or about 10/25/12: There was an accumulation of combustible residue on four paint racks, employees spray paint with flammable materials.
Recent events (3)
- — J (O) $0
- — C (S) $0
- — Z (S) $0
1910.212 A01
- Issued
- Jan 25, 2013
- Penalty
- Initial $1,951 · Current $0 Reduced
General-duty citation text
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created point of operation, rotating parts, and flying chips: a) 120 Work Center, on or about 10/25/12: Enco Drill Press was not provided with a chuck and tool guard.
Recent events (3)
- — J (S) $0
- — C (S) $1951
- — Z (S) $1951
1910.254 D09 I
- Issued
- Jan 25, 2013
- Penalty
- Initial $1,951 · Current $0 Reduced
General-duty citation text
29 CFR 1910.254(d)(9)(i) Equipment with defects or damage that created a safety hazard was not removed from use until its safety was assured by qualified personnel. a) 125 Work Center, on or about 10/25/12: The electrode holder had damaged insulation exposing the metal portion of the jaws.
Recent events (3)
- — J (O) $0
- — C (S) $1951
- — Z (S) $1951
1910.303 G02 I
- Issued
- Jan 25, 2013
- Penalty
- Initial $3,251 · Current $2,275 Reduced
General-duty citation text
29 CFR 1910.303(g)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by approved cabinets or other forms of approved enclosures, or other means listed under this provision: a) 125 Work Center, on or about 10/25/12: A 120/208 volt breaker panel box P5 located had two blanks missing.
Recent events (3)
- — J (O) $2275
- — C (S) $3251
- — Z (S) $3251
More inspections in this industry (NAICS 333319)
More inspections in NY
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337104798.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.