Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ONGNA WOOD PRODUCTS INC.

Referral inspection · Health discipline

On , OSHA opened a referral health inspection of ONGNA WOOD PRODUCTS INC. in W. 3535 CO. RD. OO, SHEBOYGAN FALLS, WI 53085 (NAICS 321920). OSHA activity number 337113187.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Ongna Wood Products INC. — free Get an email when a new federal OSHA severe-injury report for Ongna Wood Products INC. is published. One employer, no account, unsubscribe in one click.
Site address
W. 3535 CO. RD. OO
City
SHEBOYGAN FALLS
State
WI
ZIP
53085
Mailing
W. 3535 CO. RD. OO, SHEBOYGAN FALLS, WI 53085
Inspection type
Referral (C)
Scope
Partial (B)
Discipline
Health
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
321920
Employees
33
Ownership type
A

5 citations on file for this inspection.

1910.23 A03

Serious Gravity 1 1 instance 2 exposed
Issued
Mar 1, 2013
Abate by
Mar 9, 2013
Penalty
Initial $2,100 · Current $1,470 Reduced
29 CFR 1910.23(a)(3):   Every hatchway and chute floor opening was not guarded:    a)  On or before 11/6/2012, the chute opening for a belt conveyor to the chipper was equipped with a door cover, which was left open.                                           Abatement Certification and Documentation is required.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2100

1910.156 B01

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 1, 2013
Abate by
May 7, 2013
Penalty
Initial $2,800 · Current $1,960 Reduced
29 CFR 1910.156(b)(1):     The employer elected to establish a fire brigade, and a statement or written policy was not maintained which establishes the existence of a fire brigade; the basic organizational structure, the type, amount and frequency of training:      a)    As of  10/1/2012 and 11/6/2012, the employer had not established a written policy describing the organization and training for employees who were called as a fire brigade to help extinguish a combustible dust fire, which generated heavy smoke within an enclosed ventilation duct.                                      Abatement Certification and Documentation is required.
Recent events (2)
  • — I (S) $1960
  • — Z (S) $2800

1910.156 C01

Serious Gravity 5 1 instance 6 exposed
Issued
Mar 1, 2013
Abate by
May 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.156(c)(1):     The employer did not provide training and education commensurate with those duties and functions that fire brigade members were expected to perform, prior to performing fire brigade emergency activities:    a)  As of  10/1/2012 and 11/6/2012, the employer had not provided fire brigade training for employees who were called to extinguish a combustible dust fire, which generated heavy smoke within an enclosed ventilation duct.  The employees had not been trained in the hazards of a combustible dust fire, the risk of accelerating or spreading the fire by trying to open the ventilation pipe at the location of smoldering combustible dust, or in the use of personal protective equipment (PPE) for smoke and fire exposure.                                     Abatement Certification and Documentation is required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 G01 I A

Serious Gravity 1 1 instance 12 exposed
Issued
Mar 1, 2013
Abate by
May 7, 2013
Penalty
Initial $2,100 · Current $1,470 Reduced
29 CFR 1910.303(g)(1)(i)(A):     For electric equipment operating at 600 volts, nominal, or less to ground, and likely to require examination, adjustment, servicing, or maintenance while energized, the depth of the working space in the direction of access to live parts (as measured from the live parts where they were exposed or from the enclosure front or opening where they were enclosed) was less than indicated in Table S-1 of Subpart S of Part 1910:      a) On or before 11/6/2012,  electrical breaker boxes and shutoff boxes on the west wall of the cutting room were blocked from access by pallet storage.  There was not a three foot or more clearance around the boxes, nor a means to reach them.                                       Abatement Certification and Documentation is required.
Recent events (2)
  • — I (S) $1470
  • — Z (S) $2100

1910.307 C

Serious Gravity 1 1 instance 12 exposed
Issued
Mar 1, 2013
Abate by
May 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.307(c):   Equipment, wiring methods, and installations of equipment in hazardous (classified) locations were not intrinsically safe, approved for the hazardous (classified) location, or safe for the hazardous (classified) location:    a)    On or before 11/6/2012, an electrical outlet on the south wall, beneath an overhead conveyor connection, was covered in accumulated wood dust.   The fixture was not protected from intrusion of combustible material into the outlet area.                                       Abatement Certification and Documentation is required.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Ongna Wood Products INC.'s full OSHA safety record →