Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: MASTERS MASONRY OF ST. AUGUSTINE, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MASTERS MASONRY OF ST. AUGUSTINE, INC. in 310 6TH STREET, ATLANTIC BEACH, FL 32233 (NAICS 238140). OSHA activity number 337126189.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Masters Masonry of ST. Augustine, INC. — free Get an email when a new federal OSHA severe-injury report for Masters Masonry of ST. Augustine, INC. is published. One employer, no account, unsubscribe in one click.
Site address
310 6TH STREET
City
ATLANTIC BEACH
State
FL
ZIP
32233
Mailing
39 MASTERS DRIVE, SAINT AUGUSTINE, FL 32084
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
7
Ownership type
A

5 citations on file for this inspection.

1926.100 A

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 19, 2012
Penalty
Initial $2,200 · Current $1,320 Reduced
29 CFR 1926.100(a): Employees were not protected by protective helmets while working in areas where there was a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns:    a. On or about October 30, 2012, employees working at ground level in close proximity to a scaffold were not wearing hard hats, exposing themselves to the hazard of being struck by falling bricks and other materials.
Recent events (2)
  • — I (S) $1320
  • — Z (S) $2200

1926.451 C02

Serious Gravity 10 2 instances 2 exposed
Issued
Nov 19, 2012
Penalty
Initial $3,080 · Current $1,848 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:    a. On or about October 30, 2012, on the west side of the chimney, the scaffold legs did not have screw jacks and base plates, exposing employees to a scaffold collapse hazard.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3080

1926.451 C02 I

Serious Gravity 10 2 instances 2 exposed
Issued
Nov 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.451(c)(2)(i): Footings were not level, sound, rigid and capable of supporting the loaded scaffold without settling or displacement:    a. On or about October 30, 2012, on the west side of the chimney, the scaffold legs was set on concrete blocks, exposing employees to a scaffold collapse hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.452 C02

Serious Gravity 10 1 instance 2 exposed
Issued
Nov 19, 2012
Penalty
Initial $0 · Current $0
29 CFR 1926.452(c)(2): Tubular welded frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would have secured vertical members together laterally:    a. On or about October 30, 2012, on the west side of the chimney, the scaffold did not have enough cross bracing, exposing employees to a scaffold collapse hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1926.451 G01

Serious Gravity 10 4 instances 4 exposed
Issued
Nov 19, 2012
Penalty
Initial $3,080 · Current $1,848 Reduced
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section:    a. On or about October 30, 2012, on the west side of the chimney, the 4th level of the scaffold did not have guardrails on the end of the platform or on the open sides of the material platform, exposing employees to an 18 feet fall hazard.     b. On or about October 30, 2012, on the south side of the chimney, the 4th level of the scaffold had a walkway platform without a guardrail, exposing employees to an 18 feet fall hazard.
Recent events (2)
  • — I (S) $1848
  • — Z (S) $3080

View Masters Masonry of ST. Augustine, INC.'s full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337126189.