EVANSTON, IL —
OSHA Inspection: REMZO MUSIC
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of REMZO MUSIC in 2333 CENTRAL, EVANSTON, IL 60202 (NAICS 238350). OSHA activity number 337154587.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- REMZO MUSIC
- Site address
- 2333 CENTRAL
- City
- EVANSTON
- State
- IL
- ZIP
- 60202
- Mailing
- 485 ROYAL OAKS, WOOD DALE, IL 60191
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238350
- Employees
- 3
- Ownership type
- A
Citations
6 citations on file for this inspection.
1903.19 C01
- Issued
- Apr 12, 2013
- Abate by
- May 15, 2013
- Penalty
- Initial $400 · Current $400
General-duty citation text
29 CFR 1903.19(c)(1): The employer did not certify to OSHA, within 10 calendar days after the abatement date, that the cited violation had been abated: Remzo Music dba Scope of Work, failed to certify to OSHA within 10 calendar days after the abatement date that each of the following cited violations had been corrected: Citation Number Item Number Abatement Date 01 01 12/19/2012 01 02 12/19/2012 01 03 12/19/2012 01 04a 01/28/2013 01 04b 01/28/2013 In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).
Recent events (1)
- — Z (O) $400
1926.451 B01 I
- Issued
- Dec 7, 2012
- Abate by
- Dec 19, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(b)(1)(i): Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) was not installed so that the space between adjacent units and the space between the platform and the uprights were no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary: a) Employer did not ensure that the working levels of the supported scaffolding system were completely planked. Employees were exposed to falling up to approximately 25 feet to the lower levels of the site. **In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.**
Recent events (1)
- — Z (S) $2800
1926.451 E01
- Issued
- Dec 7, 2012
- Abate by
- Dec 19, 2012
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, sturcure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access: a) Employees were not provided a safe means to access/egress the working levels of the supported scaffolding system. Employees were observed climbing the cross bracing of the scaffolding system. **In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).**
Recent events (1)
- — Z (S) $2000
1926.451 G01
- Issued
- Dec 7, 2012
- Abate by
- Dec 19, 2012
- Penalty
- Initial $2,800 · Current $2,800
General-duty citation text
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) Employer did not ensure that the employees were protected from falling from the working levels of the supported scaffolding system. Employees were exposed to falling up to approximately 25 feet to the lower levels of the site. **In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification. This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence of abatement, or other written records.**
Recent events (1)
- — Z (S) $2800
1926.454 A
- Issued
- Dec 7, 2012
- Abate by
- Jan 28, 2013
- Penalty
- Initial $2,000 · Current $2,000
General-duty citation text
29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards: a) The employer did not ensure that its employees were trained to recognize, control or minimize the hazards associated with the use of the tubular welded framed scaffolding system utilized at the site. **In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).**
Recent events (1)
- — Z (S) $2000
1926.454 B
- Issued
- Dec 7, 2012
- Abate by
- Jan 28, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1926.454(b): The employer did not have each employee involved in erecting, disassembling, moving, operating, repairing, maintaining, or inspecting a scaffold trained by a competent person to recognize any hazards associated with the work in question: a) The employer did not ensure that its employees were trained to recognize, control or minimize the hazards associated with the erection, operation and maintenance of the scaffolding system utilized at the site. **In accordance with 29 CFR 1903.19(c), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).**