Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: HIGH BALL ERECTORS

Unprogrammed Related inspection · Safety discipline

On , OSHA opened an unprogrammed Related safety inspection of HIGH BALL ERECTORS in 10081 WADSWORTH PARKWAY, WESTMINSTER, CO 80504 (NAICS 238120). OSHA activity number 337155980.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch High Ball Erectors — free Get an email when a new federal OSHA severe-injury report for High Ball Erectors is published. One employer, no account, unsubscribe in one click.
Establishment
HIGH BALL ERECTORS
Site address
10081 WADSWORTH PARKWAY
City
WESTMINSTER
State
CO
ZIP
80504
Mailing
11678 MNTGOMERY CIRCLE, LONGMONT, CO 80504
Inspection type
Unprogrammed Related (G)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238120
Employees
4
Ownership type
A

2 citations on file for this inspection.

1926.752 B

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 19, 2012
Abate by
Dec 8, 2012
Penalty
Initial $1,870 · Current $1,309 Reduced
29 CFR 1926.752(b): A steel erection contractor erected steel without receiving written notification that the concrete in the footings, piers and walls and the mortar in the masonry piers and walls had attained, on the basis of an appropriate ASTM standard test method of field cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during steel erection activities:    (a) High Ball Erectors @ 10081Wadsworth Parkway, Westminster, CO. On or before October 11, 2012, the steel erection contractor did not ensure that the general contractor provided them with the following written notifications prior to commencement of structural steel erection activities on the job site.    (1)The concrete in the footings, piers and walls and the mortar in the masonry piers and walls have attained, on the basis of an appropriate ASTM standard test method of field-cured samples, either 75 percent of the intended minimum compressive design strength or sufficient strength to support the loads imposed during steel erection. This condition exposed employees to struck-by hazards.     (2) Any repairs, replacements and modifications to the anchor bolts were conducted in accordance with 1926.755(b).
Recent events (2)
  • — I (S) $1309
  • — Z (S) $1870

1926.701 B

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 19, 2012
Abate by
Dec 8, 2012
Penalty
Initial $1,870 · Current $1,309 Reduced
29 CFR 1926.701(b):  All protruding reinforcing steel, onto and/or into which employees could fall or come against, shall be guarded to eliminate the hazard of impalement:    High Ball Erectors @ 10081Wadsworth Parkway, Westminster, CO. On or before October 11, 2012 the exposing employer did not ensure each reinforcing re-bar, which was sticking up 42 above the foundation was guarded to eliminate the hazard of impalement.  Steel erector employees were working above the unguarded re-bar on the south end foundation wall.   This condition exposed employees to an impalement hazard.
Recent events (2)
  • — I (S) $1309
  • — Z (S) $1870

View High Ball Erectors's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337155980.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.