TAMPA, FL ·
OSHA Inspection: MARLYN STEEL DECKS, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of MARLYN STEEL DECKS, INC. in 6808 HARNEY RD., TAMPA, FL 33610 (NAICS 332322). OSHA activity number 337157986.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- MARLYN STEEL DECKS, INC.
- Site address
- 6808 HARNEY RD.
- City
- TAMPA
- State
- FL
- ZIP
- 33610
- Mailing
- 6808 HARNEY RD., TAMPA, FL 33610
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 332322
- Employees
- 16
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1910.219 D01
- Issued
- Dec 18, 2012
- Penalty
- Initial $1,445 · Current $867 Reduced
General-duty citation text
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):(a) a) For the establishment at 6808 Harney Rd., Tampa, FL 33610, as observed on or about 11/01/2012, employees were exposed to potential amputation hazards associated with two unguarded belt and pulley drive systems for air compressors.
Recent events (2)
- · I (S) $867
- · Z (S) $1445
1910.147 C04 II
- Issued
- Dec 18, 2012
- Abate by
- Jan 8, 2013
- Penalty
- Initial $0 · Current $0
General-duty citation text
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section: For the establishment at 6808 Harney Rd., Tampa, FL 33610, as observed on or about 11/01/2012, specific lockout-tagout procedures addressing all hazardous energy present were not available for the following equipment on which maintenance was performed: a) Mar-Ribb Metal machines 110V/240V electricity and compressed air b) Jorns Metal Folder 110V/240V electricity and compressed air c) PBR machine 110V/240V electricity and compressed air
Recent events (2)
- · I (O) $0
- · Z (O) $0
More inspections in this industry (NAICS 332322)
More inspections in FL
Source
This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). OSHA publishes its own view of this case as inspection number 337157986.
Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.