Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,645Inspections Most recent open 2026-07-16 Last loaded 2026-07-20

OSHA Inspection: MARLYN STEEL DECKS, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of MARLYN STEEL DECKS, INC. in 6808 HARNEY RD., TAMPA, FL 33610 (NAICS 332322). OSHA activity number 337157986.

Watch Marlyn Steel Decks, INC. — free Get an email when a new federal OSHA severe-injury report for Marlyn Steel Decks, INC. is published. One employer, no account, unsubscribe in one click.
Site address
6808 HARNEY RD.
City
TAMPA
State
FL
ZIP
33610
Mailing
6808 HARNEY RD., TAMPA, FL 33610
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
332322
Employees
16
Ownership type
A

2 citations on file for this inspection.

1910.219 D01

Serious Gravity 5 1 instance 11 exposed
Issued
Penalty
Initial $1445.00 · Current $867.00 Reduced
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):(a)     a) For the establishment at 6808 Harney Rd., Tampa, FL 33610, as observed on or about 11/01/2012, employees were exposed to potential amputation hazards associated with two unguarded belt and pulley drive systems for air compressors.
Recent events (2)
  • — I (S) $867
  • — Z (S) $1445

1910.147 C04 II

Other-than-serious 3 instances 11 exposed
Issued
Abate by
Penalty
Initial $0.00 · Current $0.00
29 CFR 1910.147(c)(4)(ii): The energy control procedures did not clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, including, but not limited to Items of this section:    For the establishment at 6808 Harney Rd., Tampa, FL 33610, as observed on or about 11/01/2012, specific lockout-tagout procedures addressing all hazardous energy present were not available for the following equipment on which maintenance was performed:         a) Mar-Ribb Metal machines  110V/240V electricity and compressed air       b) Jorns Metal Folder  110V/240V electricity and compressed air       c) PBR machine  110V/240V electricity and compressed air
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

JELD-WEN

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337157986.