OSHA Inspection: FIVE-O MARKETING SERVICES, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of FIVE-O MARKETING SERVICES, INC. in 115 MOKAUEA ST., HONOLULU, HI 96819 (NAICS 424410). OSHA activity number 337168611.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Five-O Marketing Services, INC. — free Get an email when a new federal OSHA severe-injury report for Five-O Marketing Services, INC. is published. One employer, no account, unsubscribe in one click.
Site address
115 MOKAUEA ST.
City
HONOLULU
State
HI
ZIP
96819
Mailing
115 MOKAUEA ST., HONOLULU, HI 96819
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
424410
Employees
46
Ownership type
A

5 citations on file for this inspection.

1910.151 C

Deleted Serious Gravity 5 1 instance 15 exposed
Issued
Nov 13, 2012
Abate by
Dec 10, 2012
Penalty
Initial $2,380 · Current $0 Reduced
29 CFR 1910.151(c): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use:    a) The employer did not assure that facilities for quick drenching or flushing of the eyes was provided  to employees who may be injured by corrosive materials when using the forklift battery charging station.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2380

1910.178 P01

Serious Gravity 5 1 instance 15 exposed
Issued
Nov 13, 2012
Abate by
Dec 3, 2012
Penalty
Initial $2,975 · Current $1,900 Reduced
29 CFR 1910.178(p)(1): Where powered industrial trucks were found to be in need of repair, defective, or in any way unsafe, the trucks were not taken out of service until they had been restored to safe operating condition:    a)The employer did not assure that the Clark GCS17 forklift (s/n G12700356792) was removed from service during a time in which it was not in safe operating condition.  Employees were exposed to injury in that the operators seat was detached from the lift and the horn was not operative.       In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1900
  • — Z (S) $2975

1910.178 Q07

Serious Gravity 5 1 instance 15 exposed
Issued
Nov 13, 2012
Abate by
Dec 3, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.178(q)(7): Industrial trucks were not examined before being placed in service, or were placed in service if the examination showed conditions adversely affecting the safety of the vehicle:    a) Forklifts were not inspected daily for conditions that adversely affect the trucks safety before being placed in service.  Employees operate forklifts daily to move materials within the warehouse and to load/unload delivery trucks.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.305 B01 II

Serious Gravity 1 1 instance 10 exposed
Issued
Nov 13, 2012
Abate by
Dec 3, 2012
Penalty
Initial $1,785 · Current $1,400 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed:    a) The employer did not assure that an unused opening in the circuit breaker box, located in the panel used to control the forklift battery charging station, was closed to protect employees from the live parts.  Employees that accessed the cabinet to power on/off the battery charging station were exposed to electrical hazards.    In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET), and in addition, documentation demonstrating that abatement is complete must be included with your certification.  This documentation may include, but is not limited to, evidence of the purchase or repair of the equipment, photographic or video evidence, or written records.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $1785

1910.303 G01

Other-than-serious 1 instance 15 exposed
Issued
Nov 13, 2012
Abate by
Nov 26, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1): Sufficient access and working space was not provided and maintained about all electric equipment (operating at 600 volts, nominal, or less to ground) to permit ready and safe operation and maintenance of such equipment:    a) The employer did not assure that access to the electrical distribution panel(s), located in the bakery area, was maintained with at least three feet clear space.  The area in front of the electrical equipment was blocked by a battery charging station, hindering an employees ability to access the equipment.      In accordance with 29 CFR 1903.19(d), abatement certification is required for this violation (using the CERTIFICATION OF CORRECTIVE ACTION WORKSHEET).