Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: JBL HAWAII, LTD.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of JBL HAWAII, LTD. in 905 KOKEA STREET, HONOLULU, HI 96817 (NAICS 423710). OSHA activity number 337169213.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch JBL Hawaii, LTD. — free Get an email when a new federal OSHA severe-injury report for JBL Hawaii, LTD. is published. One employer, no account, unsubscribe in one click.
Establishment
JBL HAWAII, LTD.
Site address
905 KOKEA STREET
City
HONOLULU
State
HI
ZIP
96817
Mailing
905 KOKEA STREET, HONOLULU, HI 96817
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423710
Employees
47
Ownership type
A

6 citations on file for this inspection.

1910.157 G02

Serious Gravity 5 1 instance 6 exposed
Issued
Nov 8, 2012
Abate by
Dec 14, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.157(g)(2):     The educational program to familiarize employees with the general principles of fire extinguisher use and the hazards involved with incipient stage fire-fighting was not provided to all employees at least annually:  a) On or about 11/1/12 throughout the site; employer provides portable fire extinguisher for all employees to use on fires associated with woodworking and welding activites.  The last educational program was provided April 2011.    Abatement Certification
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.212 A01

Serious Gravity 5 1 instance 4 exposed
Issued
Nov 8, 2012
Abate by
Dec 14, 2012
Penalty
Initial $2,800 · Current $2,000 Reduced
29 CFR 1910.212(a)(1):     One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:    a) On or about 11/1/12 in the weld shop; the hollow metal cut saw ( Original Metal Saw company - model 3579 - serial # 051010851 )  did not have guard on the lower portion of the saw blade exposing employees to contact with moving part.   Abatement Certification
Recent events (2)
  • — I (S) $2000
  • — Z (S) $2800

1910.303 B07 I

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2012
Abate by
Dec 14, 2012
Penalty
Initial $2,800 · Current $1,400 Reduced
29 CFR 1910.303(b)(7)(i):     Unused openings in boxes, raceways, auxiliary gutters, cabinets, equipment cases, or housings were not effectively closed to afford protection substantially equivalent to the wall of the equipment    a) On or about 11/2/12 in the wood shop; the wall mouted four plug outlet box located near the doorway to the area was missing a knockout exposing the conductors.    Abatement Certification
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2800

1910.303 B07 IV

Serious Gravity 5 1 instance 2 exposed
Issued
Nov 8, 2012
Abate by
Dec 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(b)(7)(iv):     There were damaged parts that could adversely affect safe operation or mechanical strength of the equipment, such as parts that were broken, bent, cut, or deteriorated.   a) On or about 11/2/12 in the wood shop; the wiring on the motor located at the top of the Magnum ( Norfield - serial # DJ1718M ) was broken and deteriorated in at least two locations exposing the conductors.    Abatement Certification
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.303 F02

Other-than-serious 1 instance 4 exposed
Issued
Nov 8, 2012
Abate by
Dec 14, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(f)(2):     Each service, feeder, and branch circuit, at its disconnecting means or overcurrent device, was not legibly marked to indicate its purpose, nor located and arranged so the purpose was evident:  a) On or about in the Weld shop; the circuit breakers inside the GE brand A Series panel board 208 volts AC 3 phase ( Serial # AQU324ABX ) electrical panel located on the alley side wall of the shop were not marked.    Abatement Certification
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

1910.303 G01

Other-than-serious 1 instance 4 exposed
Issued
Nov 8, 2012
Penalty
Initial $0 · Current $0
29 CFR 1910.303(g)(1):     Sufficient access and working space was not provided and maintained about all electric equipment to permit ready and safe operation and maintenance of such equipment.   a) On or about in the Weld shop; a long piece of plywood was leaning against and partially covering the front of the GE brand A Series panel board 208 volts AC 3 phase ( Serial # AQU324ABX ) electrical panel and a floor fan was stored directly in front of the electrical panel effectively blocking access and use.      Abatement Certification
Recent events (2)
  • — I (O) $0
  • — Z (O) $0

View JBL Hawaii, LTD.'s full OSHA safety record →