OSHA Inspection: F W M MECHANICAL

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of F W M MECHANICAL in 1200 DAVENPORT DR., MINDEN, LA 71058 (NAICS 331210). OSHA activity number 337175004.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch F W M Mechanical — free Get an email when a new federal OSHA severe-injury report for F W M Mechanical is published. One employer, no account, unsubscribe in one click.
Establishment
F W M MECHANICAL
Site address
1200 DAVENPORT DR.
City
MINDEN
State
LA
ZIP
71058
Mailing
1200 DAVENPORT DR., MINDEN, LA 71058
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
331210
Employees
36
Ownership type
A

10 citations on file for this inspection.

1910.147 C01

Serious Gravity 10 4 instances 8 exposed
Issued
Dec 11, 2012
Abate by
Jan 29, 2013
Penalty
Initial $4,900 · Current $1,750 Reduced
29 CFR 1910.147(c)(1): Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative.      a) The employer did not develop written procedures with specific steps for the control of potentially hazardous energy regarding machines and equipment such as, but not limited to:        1. Cut up area;             a) Willabrator Blasting Machine            b) Control Angle Iron            c) Horizontal Bandsaw        2.  Prefab area; Ocean Avenger Drill
Recent events (2)
  • — I (S) $1750
  • — Z (S) $4900

1910.179 G01 V

Serious Gravity 1 5 instances 15 exposed
Issued
Dec 11, 2012
Abate by
Dec 20, 2012
Penalty
Initial $1,785 · Current $1,050 Reduced
29 CFR 1910.179(g)(1)(v): Pendant control boxes shall be constructed to prevent electrical shock and shall be clearly marked for identification of functions.      a) Throughout the facility; the employer failed to ensure that overhead jib cranes had the buttons marked to identify its functionality.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $1785

1910.212 A03 II

Serious Gravity 1 2 instances 8 exposed
Issued
Dec 11, 2012
Abate by
Dec 27, 2012
Penalty
Initial $1,785 · Current $1,050 Reduced
29 CFR 1910.212(a)(3)(ii): The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.      a) The following pieces of equipment did not have a guard around the bit to prevent a point of operation injury:         1. In the cut up area a magnetic drill.         2. In the maintenance shop a Bridgeport milling machine
Recent events (2)
  • — I (S) $1050
  • — Z (S) $1785

1910.212 B

Serious Gravity 1 1 instance 5 exposed
Issued
Dec 11, 2012
Abate by
Dec 20, 2012
Penalty
Initial $1,785 · Current $1,050 Reduced
29 CFR 1910.212(b): Anchoring fixed machinery. Machines designed for a fixed location shall be securely anchored to prevent walking or moving.      a) Cut up area; a 6 inch Dayton dual bench grinder, Model 4Z123G was not secured from moving or walking during use.  Inadvertent movement of the grinder could cause work piece slippage and loss of control resulting in employee injury and/or abrasive wheel breakage.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $1785

1910.215 B09

Serious Gravity 1 2 instances 5 exposed
Issued
Dec 11, 2012
Abate by
Dec 20, 2012
Penalty
Initial $1,785 · Current $0 Reduced
29 CFR 1910.215(b)(9): Exposure adjustment. Safety guards of the types described in Subparagraphs (3) and (4) of this paragraph, where the operator stands in front of the opening, shall be constructed so that the peripheral protecting member can be adjusted to the constantly decreasing diameter of the wheel.       a) Cut up area; the employer failed to ensure a Dayton 6" dual bench grinder had tongue guards to prevent struck-by injuries in the event of a wheel breakage.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1785

1910.242 B

Deleted Serious Gravity 5 5 instances 8 exposed
Issued
Dec 11, 2012
Abate by
Dec 21, 2012
Penalty
Initial $2,975 · Current $0 Reduced
29 CFR 1910.242(b): Compressed air used for cleaning. Compressed air shall not be used for cleaning purposes except where reduced to less than 30 p.s.i. and then only with effective chip guarding and personal protective equipment.      a) Throughout the work area; air nozzles are routinely used for cleaning at compressed air pressures up to 90 psig.  Multiple air nozzles were found exceeding the pressure of 30 psig.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2975

1910.252 B02 III

Deleted Serious Gravity 1 5 instances 45 exposed
Issued
Dec 11, 2012
Abate by
Dec 26, 2012
Penalty
Initial $1,785 · Current $0 Reduced
29 CFR 1910.252(b)(2)(iii): Protection from arc welding rays. Where the work permits, the welder should be enclosed in an individual booth painted with a finish of low reflectivity such as zinc oxide (an important factor for absorbing ultraviolet radiations) and lamp black, or shall be enclosed with noncombustible screens similarly painted. Booths and screens shall permit circulation of air at floor level. Workers or other persons adjacent to the welding areas shall be protected from the rays by noncombustible or flameproof screens or shields or shall be required to wear appropriate goggles.      a) Throughout work facility; welding stations were not shielded or otherwise screened off to protect workers moving throughout the facility from viewing the welding arc and exposure to ultraviolet radiation.
Recent events (2)
  • — I (S) $0
  • — Z (S) $1785

1910.305 B01 II

Serious Gravity 10 4 instances 45 exposed
Issued
Dec 11, 2012
Abate by
Dec 27, 2012
Penalty
Initial $4,900 · Current $1,050 Reduced
29 CFR 1910.305(b)(1)(ii): Unused openings in cabinets, boxes, and fittings shall be effectively closed.      a) Several electrical panelboards had uncovered circuit breaker openings that exposed employees to possible contact with live electrical conductors and the hazard of electrical shock:      1. Prefab area - Electrical panel LA 5       2. Welding area          a) 120 Volt breaker box          b) Electrical panels PB 1 and LA 1      3. Air Compressor Room - Electrical panel PB 3
Recent events (2)
  • — I (S) $1050
  • — Z (S) $4900

1910.305 G01 IV A

Serious Gravity 1 1 instance 4 exposed
Issued
Dec 11, 2012
Abate by
Dec 27, 2012
Penalty
Initial $1,785 · Current $1,050 Reduced
29 CFR 1910.305(g)(1)(iv)(A): As a substitute for the fixed wiring of a structure;      a) Between fitting stations 12 & 13; An extension cord was used as permanent wiring to power a station work light. This condition exposed employees to an electric shock hazard.
Recent events (2)
  • — I (S) $1050
  • — Z (S) $1785

1910.305 G02 II

Serious Gravity 5 1 instance 5 exposed
Issued
Dec 11, 2012
Abate by
Dec 20, 2012
Penalty
Initial $2,975 · Current $0 Reduced
29 CFR 1910.305(g)(2)(ii): Flexible cords may be used only in continuous lengths without splice or tap. Hard-service cord and junior hard-service cord No. 14 and larger may be repaired if spliced so that the splice retains the insulation, outer sheath properties, and usage characteristics of the cord being spliced.      a) Paint area; the electrical powercord from a fan was spliced together with the electrical line in the wall.     b) Diesel storage tank area; the electrical powercord from a diesel storage tank pump was spliced together with an extension cord.    The splicings exposed employees to an electric shock hazard.
Recent events (2)
  • — I (S) $0
  • — Z (S) $2975