Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: BARR ENTERPRISES

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of BARR ENTERPRISES in W7276 CHICKADEE ROAD, GREENWOOD, WI 54437 (NAICS 311111). OSHA activity number 337177786.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Barr Enterprises — free Get an email when a new federal OSHA severe-injury report for Barr Enterprises is published. One employer, no account, unsubscribe in one click.
Establishment
BARR ENTERPRISES
Site address
W7276 CHICKADEE ROAD
City
GREENWOOD
State
WI
ZIP
54437
Mailing
W7276 CHICKADEE ROAD, GREENWOOD, WI 54437
Inspection type
Planned (H)
Scope
Partial (B)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
311111
Employees
14
Ownership type
A

10 citations on file for this inspection.

1910.23 C03

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 28, 2013
Abate by
Feb 19, 2013
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.23(c)(3): Regardless of height, open-sided floors, walkways, platforms, or runways above or adjacent to dangerous equipment, pickling or galvanizing tanks, degreasing units, and similar hazards were not guarded with a standard railing and toe board.  (a) Grinding area, Feed Screw Auger:  Employees were exposed to the rotating parts of a carcass feed screw auger at floor level that was not protected by a standard rail and toe board.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.212 A01

Serious Gravity 5 1 instance 2 exposed
Issued
Jan 28, 2013
Abate by
Feb 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by point of operation, ingoing nip points, rotating parts, flying chips and sparks:  (a) Grinding area, Auger #3:  Employees exposed to the rotating parts of a seven inch auger that was not fully guarded to prevent entanglement.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C01

Serious Gravity 1 1 instance 4 exposed
Issued
Jan 28, 2013
Abate by
Feb 26, 2013
Penalty
Initial $1,200 · Current $840 Reduced
29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative:  (a) Throughout the facility; The employer did not establish and implement a control of hazardous energy (lockout/tagout) program.
Recent events (2)
  • — I (S) $840
  • — Z (S) $1200

1910.147 C07 I

Serious Gravity 1 1 instance 4 exposed
Issued
Jan 28, 2013
Abate by
Feb 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(i): The employer did not provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees:   (a)  Throughout the facility;  The employer did not train employees on the safe application and use of energy control procedures.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.147 C07 IV

Serious Gravity 1 1 instance 4 exposed
Issued
Jan 28, 2013
Abate by
Feb 22, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.147(c)(7)(iv): The employer did not certify that employee training had been accomplished and kept up to date:  (a)  Administrative office;  A certification of energy control procedure training was not maintained.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.178 L01 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 28, 2013
Abate by
Feb 26, 2013
Penalty
Initial $2,000 · Current $1,400 Reduced
29 CFR 1910.178(l)(1)(ii): The employer did not ensure that each operator had successfully completed the training required by paragraph (l), except as permitted by paragraph (l)(5), prior to permitting an employee to operate a power industrial truck:  (a) Production plant; The employer did not train and certify the forklift operator on powered industrial truck operations and permitted him to operate a powered industrial truck throughout the facility on a daily basis.
Recent events (2)
  • — I (S) $1400
  • — Z (S) $2000

1910.219 C04 I

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 28, 2013
Abate by
Feb 11, 2013
Penalty
Initial $1,600 · Current $860 Reduced
29 CFR 1910.219(c)(4)(i): Unguarded projecting shaft end(s) did not present a smooth edge and end and projected more than one half the diameter of the shaft:  (a) Grinding area, magnet/belt; Employees were exposed to an unguarded two inch diameter by five inch long protruding rotating shaft.
Recent events (2)
  • — I (S) $860
  • — Z (S) $1600

1910.219 C04 II

Serious Gravity 5 1 instance 3 exposed
Issued
Jan 28, 2013
Abate by
Feb 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(c)(4)(ii): The unused keyway(s) of projecting shaft end(s) were not filled up or covered:  (a) Grinding area, magnet/belt; Employees were exposed to an unguarded two inch diameter by five inch long protruding rotating shaft with an open keyway.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 D01

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 28, 2013
Abate by
Feb 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(d)(1): Pulley(s) with part(s) seven feet or less from the floor or work platform were not guarded in accordance with the requirements specified in 29 CFR 1910.219(m) and (o):  (a) Grinding - Pre-Break area; Employees were exposed to unguarded belt and pulley power transmission hazards that was powering the hydraulic pump.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

1910.219 E01 I

Serious Gravity 5 1 instance 1 exposed
Issued
Jan 28, 2013
Abate by
Feb 7, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.219(e)(1)(i): Horizontal belts which had both runs seven feet or less from the floor level were not guarded with a guard that extended to at least fifteen inches above the belt:  (a) Grinding - Pre-Break area; Employees were exposed to unguarded belt and pulley power transmission hazards that was powering the hydraulic pump.
Recent events (2)
  • — I (S) $0
  • — Z (S) $0

View Barr Enterprises's full OSHA safety record →

This record is reproduced from the U.S. Department of Labor Open Data API (OSHA inspection dataset). The original IMIS detail view is available at OSHA's Establishment Search for activity number 337177786.

Look up any company's OSHA accident reports by company, or browse severe injury reports by year, state, and company.