OSHA Inspection: J.S. MASONRY, INC.

Planned inspection · Safety discipline

On , OSHA opened a planned safety inspection of J.S. MASONRY, INC. in 2808 10TH AVE, TUSCALOOSA, AL 35401 (NAICS 238140). OSHA activity number 337181788.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch J.S. Masonry, INC. — free Get an email when a new federal OSHA severe-injury report for J.S. Masonry, INC. is published. One employer, no account, unsubscribe in one click.
Establishment
J.S. MASONRY, INC.
Site address
2808 10TH AVE
City
TUSCALOOSA
State
AL
ZIP
35401
Mailing
1011 MALLARD CIRCLE, TUSCALOOSA, AL 35405
Inspection type
Planned (H)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
238140
Employees
10
Ownership type
A

2 citations on file for this inspection.

1926.451 C02

Serious Gravity 5 1 instance 4 exposed
Issued
Jan 28, 2013
Abate by
Feb 1, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.451(c)(2): Supported scaffold poles, legs, posts, frames, and uprights did not bear on base plates and mud sills or other adequate firm foundation:    (a) On or about 10/31/12 - At 2808 10th Ave., Tuscaloosa, AL, employees were working from a scaffold and the frames on the east side were not on firm foundation.
Recent events (2)
  • — I (S) $1000
  • — Z (S) $2000

1926.452 C02

Serious Gravity 5 2 instances 3 exposed
Issued
Jan 28, 2013
Abate by
Feb 1, 2013
Penalty
Initial $2,000 · Current $1,000 Reduced
29 CFR 1926.452(c)(2): Frames and panels were not braced by cross, horizontal, or diagonal braces, or combination thereof, which would secure vertical members together laterally, and the cross braces were not of such length as would  automatically square and align vertical members such that the erected scaffold was always plumb, level, and square:    (a) On or about 10/31/12 - At 2808 10th Ave, Tuscaloosa, AL, employees were working on a scaffold and the frames were not braced.    (b) On or about 10/31/12 - At 2808 10th Ave, Tuscaloosa, AL, employees were working on a scaffold that was not square.
Recent events (2)