COLUMBUS, OH ·
OSHA Inspection: DAVID CARMEN
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of DAVID CARMEN in 2622 AEDEN DRIVE, COLUMBUS, OH 43219 (NAICS 238170). OSHA activity number 337184980.
OSHA opens inspections for many reasons: routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- DAVID CARMEN
- Site address
- 2622 AEDEN DRIVE
- City
- COLUMBUS
- State
- OH
- ZIP
- 43219
- Mailing
- 6396 BUSCH BLVD APARTMENT 406, COLUMBUS, OH 43229
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Complete (A)
- Discipline
- Safety
- Advance notice
- No
- Union status
- Non-union (B)
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238170
- Employees
- 2
- Ownership type
- Private (A)
Citations
2 citations on file for this inspection.
1926.451 G04 I
- Issued
- Nov 13, 2012
- Abate by
- Dec 16, 2012
- Penalty
- Initial $1,700 · Current $595 Reduced
General-duty citation text
29 CFR 1926.451(g)(4)(i): Guardrail systems shall be installed along all open sides and ends of platforms. Guardrail systems shall be installed before the scaffold is released for use by employees other than erection/dismantling crews. a. At the jobsite where employees were installing siding on a two story home from a pump jack scaffold, guardrails were not installed on the east or west ends of the scaffold, thereby exposing employees to a fall hazard.
Recent events (2)
- · I (S) $595
- · Z (S) $1700
1926.1053 B01
- Issued
- Nov 13, 2012
- Abate by
- Nov 23, 2012
- Penalty
- Initial $1,360 · Current $476 Reduced
General-duty citation text
29 CFR 1926.1053(b)(1): When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support. a. At the jobsite, employees used an extension ladder that was not 3 feet above the landing surface to gain access to the roof and pump jack scaffold, thereby exposing employees to a fall hazard.