Safety Incidents OSHA Severe Injury Reports · 2015–2025
5,189,992Inspections Most recent open 2026-07-18 Last loaded 2026-07-22

OSHA Inspection: ATLANTIC COAST MATERIALS, LLC

Referral inspection · Safety discipline

On , OSHA opened a referral safety inspection of ATLANTIC COAST MATERIALS, LLC in BETWEEN PIERS M AND N VETERANS TERMINAL, NORTH CHARLESTON, SC 29405 (NAICS 423320). OSHA activity number 337200018.

What this inspection record means

OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.

Watch Atlantic Coast Materials, LLC — free Get an email when a new federal OSHA severe-injury report for Atlantic Coast Materials, LLC is published. One employer, no account, unsubscribe in one click.
Site address
BETWEEN PIERS M AND N VETERANS TERMINAL
City
NORTH CHARLESTON
State
SC
ZIP
29405
Mailing
PO BOX 461, UPPERVILLE, VA 20185
Inspection type
Referral (C)
Scope
Complete (A)
Discipline
Safety
Advance notice
No
Union status
B
Opened
Closing conference
Case closed
Last modified
Data loaded
NAICS code
423320
Employees
3
Ownership type
A

2 citations on file for this inspection.

1910.106 G03 IV D

Other-than-serious 1 instance 2 exposed
Issued
Jan 29, 2013
Abate by
Feb 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.106(g)(3)(iv)(d): The dispensing units, were not mounted either on a concrete island or protected against collision damage by suitable means.    a) Southwest end of the worksite: A 500 gallon diesel fuel tank used to refuel vehicles and equipment was not protected from collision damage.    ABATEMENT CERTIFICATION IS REQUIRED.
Recent events (1)
  • — Z (O) $0

1910.106 G09

Other-than-serious 1 instance 2 exposed
Issued
Jan 29, 2013
Abate by
Feb 25, 2013
Penalty
Initial $0 · Current $0
29 CFR 1910.106(g)(9): Fire extinguisher(s) having a minimum approved classification of 6 B, C were not provided and located so as to be within 75 feet of each pump, dispenser, underground fill pipe opening, or lubrication or service room:    a) Southwest end of the worksite: There was not at least one fire extinguisher located within 75 feet of a 500 gallon diesel fuel tank used to refuel vehicles and equipment at the site.     ABATEMENT CERTIFIICATIN IS REQUIRED.
Recent events (1)