HATTIESBURG, MS —
OSHA Inspection: A.C. MCKINNIE MASONRY, INC.
Planned inspection · Safety discipline
At a glance
On , OSHA opened a planned safety inspection of A.C. MCKINNIE MASONRY, INC. in HWY 49 AT HWY 11, HATTIESBURG, MS 39401 (NAICS 238140). OSHA activity number 337203020.
OSHA opens inspections for many reasons — routine scheduling under a national or local emphasis program, an employee complaint or referral, or a follow-up after a reported injury. Opening or conducting an inspection is not itself an allegation or a finding that this employer broke any rule; any findings appear as the citations listed below, and citations can be contested, reduced, or withdrawn.
Where did this inspection happen?
- Establishment
- A.C. MCKINNIE MASONRY, INC.
- Site address
- HWY 49 AT HWY 11
- City
- HATTIESBURG
- State
- MS
- ZIP
- 39401
- Mailing
- 1807 OWENS POND ROAD, CHIPLEY, FL 32428
What kind of inspection was it?
- Inspection type
- Planned (H)
- Scope
- Partial (B)
- Discipline
- Safety
- Advance notice
- No
- Union status
- B
When did the case open and close?
- Opened
- Closing conference
- Case closed
- Last modified
- Data loaded
Establishment context
- NAICS code
- 238140
- Employees
- 7
- Ownership type
- A
Citations
5 citations on file for this inspection.
1926.451 B01
- Issued
- Dec 10, 2012
- Penalty
- Initial $1,700 · Current $976 Reduced
General-duty citation text
29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) a. Waffle House, Hwy 49 at Hwy 11, Hattiesburg MS - On or about October 31, 2012 employees were observed working from a scaffold platform that was not fully planked.
Recent events (2)
- — I (S) $976
- — Z (S) $1700
1926.451 E01
- Issued
- Dec 10, 2012
- Abate by
- Dec 28, 2012
- Penalty
- Initial $1,600 · Current $912 Reduced
General-duty citation text
29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. a. Waffle House, Hwy 11 at Hwy 49, Hattiesburg MS - On or about October 31, 2012 employees were observed working from a 12 feet high welded frame scaffold without having a ladder or other forms of safe access to the platform.
Recent events (2)
- — I (S) $912
- — Z (S) $1600
1926.451 G01
- Issued
- Dec 10, 2012
- Abate by
- Dec 28, 2012
- Penalty
- Initial $2,000 · Current $1,150 Reduced
General-duty citation text
29 CFR 1926.451(g)(1): Each employee on a scaffold more than 10 feet (3.1 m) above a lower level shall be protected from falling to that lower level. Paragraphs (g)(1)(i) through (vii) of this section establish the types of fall protection to be provided to the employees on each type of scaffold. Paragraph (g)(2) of this section addresses fall protection for scaffold erectors and dismantlers. Note to paragraph (g)(1): The fall protection requirements for employees installing suspension scaffold support systems on floors, roofs, and other elevated surfaces are set forth in subpart M of this part. a. Waffle House, Hwy 11 at Hwy 49, Hattiesburg MS - On or about October 31, 2012 an employee was observed working from a scaffold platform that was 12 feet above a concrete pad. Guardrails or a personal fall arrest system were not used to prevent the employee from falling and striking the concrete pad.
Recent events (2)
- — I (S) $1150
- — Z (S) $2000
1926.452 C02
- Issued
- Dec 10, 2012
- Abate by
- Dec 28, 2012
- Penalty
- Initial $1,600 · Current $912 Reduced
General-duty citation text
29 CFR 1926.452(c)(2): Frames and panels shall be braced by cross, horizontal, or diagonal braces, or combination thereof, which secure vertical members together laterally. The cross braces shall be of such length as will automatically square and align vertical members so that the erected scaffold is always plumb, level, and square. All brace connections shall be secured. a. Waffle House, Hwy 49 at Hwy 11, Hattiesburg MS - On or about October 31, 2012 employees were observed working from a 12 feet high welded frame scaffold that did not have cross bracing on the backside. A smaller unoccupied scaffold was missing cross bracing on the front side of the scaffold.
Recent events (2)
- — I (S) $912
- — Z (S) $1600
1926.701 B
- Issued
- Dec 10, 2012
- Abate by
- Dec 28, 2012
- Penalty
- Initial $2,000 · Current $1,150 Reduced
General-duty citation text
29 CFR 1926.701(b): Reinforcing steel. All protruding reinforcing steel, onto and into which employees could fall, shall be guarded to eliminate the hazard of impalement. a. Waffle House, Hwy 11 at Hwy 49, Hattiesburg MS - On or about October 31, 2012 employees were exposed to an impalement hazard due to rebar not being capped.
Recent events (2)
- — I (S) $1150
- — Z (S) $2000
More inspections in this industry (NAICS 238140)